催化极谱法直接快速测定高纯铅中痕量砷 被引量:1

DIRECT AND RAPID DETERMINATION OF TRACES OF ARSENIC IN PURE LEAD BY CATALYTIC POLAROGRAPHY
下载PDF
导出
摘要 在8羟其喹啉—抗坏血酸—硫酸钴的硫酸介质中,As(Ⅲ)产生灵敏的极谱催化波,其导数峰电位为-113V(vs.SCE)。As(Ⅲ)浓度在0001~002mg/L范围内,峰高与浓度呈线性关系,检出限为00006mg/L,该方法已用来测定高纯铅中痕量砷,结果令人满意。 In a system of 8hydroxyquinoline—ascorbic acid—CoSO4, As(Ⅲ) produces a sensitive catalytic polarographic wave with a peak potential of -113 V(vs. SCE). In the range 0001~002 mg/L, the differential peak height is linearly related to the concentration of As(Ⅲ) and the detection limit is 00006 mg/L. The method has been applied in the determination of arsenic in pure lead, obtaining satisfactory results.
出处 《矿冶工程》 EI CAS CSCD 北大核心 1998年第1期57-59,共3页 Mining and Metallurgical Engineering
关键词 催化极谱法 Arsenic, Lead, Catalytic polarograpy, Determination