摘要 运用二维非稳态导热模型对地源热泵夏季间歇运行模式地埋管换热器的换热特征进行了数值模拟,分析了间歇运行模式对地埋管换热器性能的影响。热泵停机后各处平均温度及平均线热流密度在穿透时间内将延续换热器正常运行时的变化规律;在总运行时间相同的条件下,开停机次数适当增加,可以有效改善地埋管换热器的性能。 The numerical simulation of heat transfer characteristics of buried tube heat exchanger with intermittent operation mode of ground-source heat pump is performed using two-dimensional unsteady heat conduction model. The influence of intermittent operation mode on the performance of buried tube heat exchanger is analyzed. When ground-source heat pump is stopped, during the time of penetration, the average temperature and linear heat flux will change in the same way as the heat exchanger operates. Under the condition of same total operation time, the appropriate increase of start and shutdown frequency of the heat pump can effectively improve the performance of buried tube heat exchanger.
出处 《煤气与热力》 2009年第4期3-6,共4页 Gas & Heat
基金 天津市高等学校科技发展基金项目(20060822)
关键词 地源热泵 间歇运行 地埋管换热器 性能 ground-source heat pump intermittent operation buried tube heat exchanger performance
  • 相关文献

参考文献5

二级参考文献13

  • 1赵军,宋德坤,李新国,张春雷.埋地换热器放热工况的现场运行实验研究[J].太阳能学报,2005,26(2):162-165. 被引量:19
  • 2Bose J E ,Smith M D,Spitler J D.Advances in ground source heat pump systems-an international overview[J].Proceedings of the 7th Heat Pump Conference - IEA,Beijing,2002,1:313-324.
  • 3Sanner B,Karytsas C,Mendrinos D,Rybach L.Current status of ground source heat pumps and underground thermal energy storage in europe [J].Geothermics,2003,3(2) :579-588.
  • 4James W Stevens.Coupled conduction and intermittent convective heat transfer from a buried pipe [J].Heat Transfer Engineering,2002,23(4) :34-43.
  • 5金招芬 朱颖心.建筑环境学[M].北京:中国建筑工业出版社,2004..
  • 6Stephen P K. Field Test for Ground Thermal Properties Methods and Impact on Ground Source Heat Pump Design. ASHRAE Trans, 2000, 25(4): 851-855.
  • 7长春地热开发公司,吉林大学.工程应用运行情况报告:封闭式应用地温能量供热、供冷技术开发报告集[R].长春:吉林大学,2001.
  • 8刘宪英,王勇,胡鸣明,魏唐棣.地源热泵地下垂直埋管换热器的试验研究[J].重庆建筑大学学报,1999,21(5):21-26. 被引量:49
  • 9于明志,方肇洪,李明钧.土壤冻结对地热换热器传热的影响[J].山东建筑工程学院学报,2001,16(1):42-46. 被引量:25
  • 10崔萍,刁乃仁,方肇洪.地热换热器间歇运行工况分析[J].山东建筑工程学院学报,2001,16(1):52-57. 被引量:34