摘要
低温地板采暖系统与传统的采暖系统一样,从舒适性角度出发,地板表面温度有标准的温度范围,为了研究该新型采暖地板的热工性能,总结实际运行中的规律,该文通过实验及理论分析研究相结合的方法,得出了维持室温为18、20、22℃工况下地板表面及室内空气的温度分布,总结出地板的散热量与地板表面温度与室温温差之间的关系,以及地板的散热量与供回水温度和室温温差之间的关系。
Alike as the conventional heating system, there is normal temperature range for the low temperature heating floor surface from the aspect of comfort. This paper investigates the performance and characteristic of a novel floor heating system by using the method of experiments combined with theoretical analysis. The temperature distribution of the heating floor surface and the room air is presented when the room temperature maintains at 18 ℃ ,20℃, and 22 ℃. The variation of the floor heating amount with the temperature difference between floor surface and room air is also discussed.
出处
《实验技术与管理》
CAS
北大核心
2009年第3期45-48,共4页
Experimental Technology and Management
关键词
采暖地板
温度
试验
heating floor
temperature
test