通过微油点火技术的介绍和比较,详细阐述徐州彭城电厂三期工程1 000 MW超超临界火电机组微油点火系统及其特点,针对调试中出现的问题,对涉及到炉膛安全监控系统(FSSS)中的相关逻辑和微油点火技术调试的实施关键点进行分析,可为同类型机组调试提供借鉴。
Tiny oil technology is introduced and compared in the paper.The oil-saving ignition systems and it's characteristics of 1 000 MW ultra-supercritical units are represented in detail.Aiming at the problems in debugging,the paper analyses the relevant logic which involves furnace safety supervised system(FSSS) and the key tiny oil technology.It offers a reference to similar units.
出处
《湖南电力》
2010年第S1期34-38,共5页
Hunan Electric Power
关键词
超超临界机组
微油点火
节油
调试
ultra-supercritical unit
tiny oil ignition
oil-saving
debugging