结合本厂高炉1号鼓风机防喘振控制系统改造的具体实例,介绍喘振的形成及危害,阐述防喘振控制原理及防喘振控制系统的实用方法。
According to the instance of the modification of preventing surge control system for the No.1 air blower in Lianyuan Iron & Steel Group Co.,Ltd..The formation and harm of surge are introduced,the theory and a realizing method of preventing surge are expounded.