期刊文献+

层状仿生生物活性人工软骨植入体的数字散斑相关分析 被引量:1

Full-field deformation measurement of bionic artificial cartilage/bone composites using digital speckle correlation method
下载PDF
导出
摘要 制备了一种仿生层状人工软骨/骨复合植入体,可将软骨植入体与宿主软骨的连接转变为骨-骨的界面结合,提高植入软骨固定效果.采用数字散斑等方法对仿生层状人工关节软骨/骨复合植入体的生物力学性能进行研究,比较了松质骨,PVA/骨复合体以及PVA-BG复合体在不同载荷作用下的位移变化,并从微观变形角度探讨了人工软骨/骨复合植入体中软骨层厚度对缓冲内部应力的作用. The bionic bioactive artificial cartilage/bone composites implants were prepared by casting bioactive hydrogels onto the cancellous bone according to the structures of nature cartilage.This new kind of cartilage implants could improve the inferior connection of the implants with host cartilage by means of bone-bone interfacial interaction.The digital speckle correlation method was used to investigate the bio-mechanical properties of the artificial cartilage/bone composites.The micro-deformation of the cancellous bone,PVA/bonecomposites and PVA-BG/composite under different compressed loads were compared,which could show the cushion action of the artificial cartilage in the range of microscale.
出处 《北京科技大学学报》 EI CAS CSCD 北大核心 2007年第S2期112-116,共5页 Journal of University of Science and Technology Beijing
关键词 人工软骨 力学性能 计算机辅助 信号处理 artificial cartilage mechanical property computer assisted signal processing
  • 相关文献

参考文献10

  • 1Mayne R.Cartilage collagens:What istheir function and are they involvedin articular disease?. Arthritis and Rheumatism . 1989
  • 2Nordin M,Frankel V H,Guo B F.Clinical Orthopaedics Biome-chanics. . 1993
  • 3Stammen J A,Williams S,Ku D N,Guldberg R E.Mechanical properties of a novel PVAhydrogel in shear and unconfined com-pression. Biomaterials . 2001
  • 4Gu Z Q,Xiao J M,Zhang X H.The development of artificialcartilage PVAhydrogel. Biomedical Materials and Engineering . 1998
  • 5Bay B K.A method for the measurement of detailed strain distri-butions within trabecular bone. Journal of Orthoptera Research . 1995
  • 6Yao X F,Yeh H Y,Zhao HP.Dynamic response and fracture characterization of polymer-clay nanocomposites with mode-I crack. Journal of Composite Materials . 2005
  • 7Zheng Y D,Wang YJ,Chen XF,et al.Preparation andcharac-terization of poly(vinyl alcohol)-hydroxylapatite hybrids hydro-gels. Journal of Composite Materials . 2007
  • 8Masanori Kobayashi Jyunya Toguchida and Masanori Oka.Preliminary study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus. Biomaterials . 2003
  • 9Horta J,Brostow W,Martinez G,et al.Characterization of bones by speckle interferometry. Journal of Medicine . 2003
  • 10Yao X F,,Meng L B,Jin G C.Full-field deformation measurement of fiber composite pressure vessel using digital speckle correlation method. Polymer Testing . 2005

同被引文献3

  • 1Takigawa T, Kashihara H, Urayama K, et al. Structure and mechanical properties of PVA gels weollen by various solvents[J]. Polymer, 1992, 33(11): 2334-2339.
  • 2Yao X F, Meng L B, Jin G C. Full-field deformation measurement of fiber composite pressure vessel using digital speckle correlation method[J]. Polymer Testing, 2005, 24(2): 245-251.
  • 3Chu T C, Ranson W F, Sutton M A, et al. Applications of digital image correlation techniques to experimental mechanicals[J]. Exp Mech, 1990, 25(3): 232-244.

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部