NSCL的离线ECR离子源ARTEMIS-B的研究与发展(英文)

R&D Effort at NSCL with the Off-line ECR Ion Source ARTEMIS-B
原文传递
导出
摘要 This paper reviews recent experimental work done with the off line source ARTEMIS-B at the NSCL.This source was built during the year 2005 and provides opportunities for off line development that can benefit the Coupled Cyclotron Facility(CCF)operation while minimizing the time taken away from the nuclear experimental program.The Artemis-B setup includes many beam diagnostics and a detailed description of the emittance scanner(Allison)and emittance measurement method is presented.A first beam dynamics study indicates that the analysis magnet has strong field aberrations and that the beam size in the dipole must be small in order to avoid significant beam brightness degradation.A second study compares beam brightness for different focusing systems between the ECR ion source and the analyzing magnet.Two electrostatic devices:a quadrupole triplet and a double quadrupole doublet have been tested successively and compared to a magnetic focusing solenoid.The experimental results tend to indicate a better beam brightness at smaller emittance for the electrostatic devices,although emittances measured for each focusing element were for a large part dependant on the tuning procedure developed to minimize the effects of the analyzing magnet. This paper reviews recent experimental work done with the off line source ARTEMIS-B at the NSCL.This source was built during the year 2005 and provides opportunities for off line development that can benefit the Coupled Cyclotron Facility(CCF)operation while minimizing the time taken away from the nuclear experimental program.The Artemis-B setup includes many beam diagnostics and a detailed description of the emittance scanner(Allison)and emittance measurement method is presented.A first beam dynamics study indicates that the analysis magnet has strong field aberrations and that the beam size in the dipole must be small in order to avoid significant beam brightness degradation.A second study compares beam brightness for different focusing systems between the ECR ion source and the analyzing magnet.Two electrostatic devices:a quadrupole triplet and a double quadrupole doublet have been tested successively and compared to a magnetic focusing solenoid.The experimental results tend to indicate a better beam brightness at smaller emittance for the electrostatic devices,although emittances measured for each focusing element were for a large part dependant on the tuning procedure developed to minimize the effects of the analyzing magnet.
出处 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2007年第S1期187-191,共5页 中国物理C(英文版)
基金 Supported by National Science Foundation
关键词 ECR Ion source EMITTANCE ELECTROSTATIC focusing SOLENOID ECR Ion source emittance electrostatic focusing solenoid
  • 相关文献

参考文献2

  • 1Baartman R.TRI-DN-95-21[]..
  • 2Machicoane G,,Cole D,Ottarson J et al. The Review of Scientific Instruments . 2006

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部