期刊文献+

NSCL从ECR离子源向CCF注入的离子束流动力学研究(英文)

Beam Dynamics Studies of ECR Injections for the Coupled Cyclotron Facility at NSCL
原文传递
导出
摘要 The Coupled Cyclotron Facility (CCF) has been operating at the NSCL since 2001,providing up to 160MeV/u heavy ion beams for nuclear physics experiments.Recent steps,particularly the improvement of the ECR-to-K500 injection line,were taken to improve the CCF performance.For that purpose an off-line ECR source,ARTEMIS-B,was built and used to investigate the impact on beam brightness under various source operating conditions,different initial focusing systems and current analysis dipole.Beam dynamics simulations including space-charge and 3D electrostatic field effects were performed and beam diagnostics including emittance scanner were used,leading to a better understanding of the CCF beam injection process. New initial electrostatic focusing elements such as a large-bore quadrupole triplet and a quadrupole double- doublet with compensating octupole were tested,and a new beam tuning procedure was established to improve the beam brightness for the CCF.Following these efforts,a significant increase of primary beam power out of the CCF has been achieved. The Coupled Cyclotron Facility (CCF) has been operating at the NSCL since 2001,providing up to 160MeV/u heavy ion beams for nuclear physics experiments.Recent steps,particularly the improvement of the ECR-to-K500 injection line,were taken to improve the CCF performance.For that purpose an off-line ECR source,ARTEMIS-B,was built and used to investigate the impact on beam brightness under various source operating conditions,different initial focusing systems and current analysis dipole.Beam dynamics simulations including space-charge and 3D electrostatic field effects were performed and beam diagnostics including emittance scanner were used,leading to a better understanding of the CCF beam injection process. New initial electrostatic focusing elements such as a large-bore quadrupole triplet and a quadrupole double- doublet with compensating octupole were tested,and a new beam tuning procedure was established to improve the beam brightness for the CCF.Following these efforts,a significant increase of primary beam power out of the CCF has been achieved.
出处 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2007年第S1期196-200,共5页 中国物理C(英文版)
基金 Supported by National Science Foundation under grant PHY-0110253
关键词 ECR injection ELECTROSTATIC QUADRUPOLE focusing analysis DIPOLE ECR injection electrostatic quadrupole focusing analysis dipole
  • 相关文献

参考文献6

  • 1Machicoane G,,Cole D,Ottarson J et al. The Review of Scientific Instruments . 2006
  • 2Stetson J W,,Machicoane G,Miller Pet al.Experimen- tal Studies of Electrostatic and Solenoidal Focusing of Low Energy Heavy Ion ECRIS beams at NSCL/MSU[].proceed- ings of theⅩⅫⅠLinac Conference.2006
  • 3Kazarinov N Yu. The Review of Scientific Instruments . 2004
  • 4ZHAO Q,,Balabin A,Marti F et al.Simulations of Solenoid and Electrostatic Quadrupole Focusing of High Intensity Beams from ECR Ion Source[].proceedings of PAC.2005
  • 5Baartman R.Aberrations in Electrostatic Quadrupoles[].TRI-DN--TRIUMF.1999
  • 6Spaedtke P.KOBRA3-INP[]..2005

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部