摘要
通过对二电场电除尘器 -文丘里水膜除尘器组合除尘方式的模拟试验研究 ,取得了大量的试验数据 ,为中、小型火电厂文丘里水膜除尘器的改造提供了一种施工周期短、改造投资费用少、综合除尘效率达 99.9%的技术方案 。
It has discribed the simulating experiments performed on the combination of electrostatic precipitator(ESP)and Venturi_collector.In order to provide experience for reforming the existing Venturi_collector with middle or small units in coal_fired power station and meet the requirement,an technical upgrading option with short construction period and less nital costs has been introduced,The comprehensive efficiency is upto 99.9%.It has reached the environment stanstard of the state.
出处
《河南理工大学学报(自然科学版)》
CAS
2001年第6期439-442,共4页
Journal of Henan Polytechnic University(Natural Science)
关键词
电除尘器
文丘里水膜除尘器
改造
模拟实验
electrostatic precipitator
Venturi*.collector
combination
simulating experiment