Implantation of dual chamber pacemaker defibrillator and placement of endocardial leads via the axillary vein

置入双腔起搏心脏复律除颤器及经腋静脉送入心内电极的初步临床体会(英文)
原文传递
导出
摘要 Objectives To assess the preliminary clinical results of implantation of dual chamber pacemaker defibrillator and to evaluate the safety and effectiveness of placement of endocardial leads in the axillary vein. Methods Seven patients with ventricular tachycardia and/or ventricular fibrillation (VT/VF), associated with bradyarrhythmia received implantation of a dual chamber pacemaker defibrillator, including 5 patients with coronary artery disease and 2 patients with dilated cardiomyopathy.The atrial and ventricular leads were introduced via the axillary vein under venographic guidance. Results Dual chamber pacemaker defibrillators were successfully implanted in the left chest subcutaneous pocket in 5 patients and the left pectoral muscular pocket in 2 patients. All the VT/VF occurring either inducibly during the procedure or spontanuously during follow-up were detected promptly and treated successfully. Both the pacing and sensing functions were satisfactory. The endocardial leads required were successfully introduced via the axillary vein without major complications.Conclusion Dual chamber pacemaker defibrillators can provide reliable therapy for VT/VF and the dual chamber pacing function. Placement of endocardial leads via the axillary vein under venographic guidance is safe and effective. 目的 初步评价新型双腔起搏心脏复律除颤器抗室性心动过速 /室颤 (VT/VF)及心动过缓起搏的临床效果 ,了解经腋静脉送入心房及心室电极的安全性及有效性。方法  7例室性心动过速及或室颤同时伴有心动过缓患者接受了双腔起搏心脏复律除颤器治疗 ,其中冠心病 5例、扩张性心肌病 2例。心房及心室电极均在X光线透视、静脉注入造影剂指导下 ,直接穿刺腋静脉 ,从该静脉送入。结果 脉冲发生器埋在左上胸皮下 5例 ,胸大肌与胸小肌之间 2例。仪器对所有VT/VF均能及时识别并成功治疗 ,同时提供有效的房室顺序起搏功能。所有心内电极均成功地经腋静脉送入 ,无并发症。结论 双腔起搏心脏复律除颤器不但能有效地治疗严重室性心律失常 ,而且能提供可靠的房室顺序性起搏功能 ,且经腋静脉送入电极安全 ,可靠。
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2001年第6期8-10,101,共4页 中华医学杂志(英文版)
关键词 dual chamber pacemaker defibrillator · arrhythmia · axillary vein 心脏复律除颤器 心律失常 腋静脉
  • 相关文献

参考文献11

  • 1Ramza BM,Rosenthal L,Hui R,et al.Safety and effectiveness of placement of pacemaker and defibrillator leads in the axillary vein guided by contrast venography. The American Journal of Cardiology . 1997
  • 2Nunain SO,Roelke M,Trouton T,et al.Limitations and late complications of third-generation automatic cardioverter defibrillators. Circulation . 1995
  • 3Osswald S,Cron TA,Sterns L,et al.New ICD-technologies:first clinical experience with dual-chamber sensing for differentiation of supraventricular tachyarrhythmias. Pacing and Clinical Electrophysiology . 1998
  • 4Lavergne T,Daubert JC,Chauvin M,et al.Preliminary clinical experience with the first dual chamber pacemaker defibrillator. Pacing and Clinical Electrophysiology . 1997
  • 5Aggarwal RK,Connelly DT,Ray SG.Early complication of permanentpacemaker implantation: no difference between dual and single chambersystems. British Heart Journal . 1995
  • 6Parsonnet V,Bernstein AD,Lindsay B.Pacemaker-implantation complication rates: an analysis of some contributing factors. Journal of the American College of Cardiology . 1989
  • 7Kazama S,Nishiyama K,Machii M.Long-term follow up of ventricular endocardial pacing leads.Complication, electrical performance, and longevity of 561 right ventricular lead. Japanese Heart Journal . 1993
  • 8Grimm W,Flores BF,Marchlinski FE.Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators. Pacing and Clinical Electrophysiology . 1992
  • 9Schmitt C,Montero M,Melichercik J.Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators. Pacing and Clinical Electrophysiology . 1994
  • 10Hook BG,Callans DJ,Kleiman RB,et al.Implantable cardioverter-defibrillator therapy in the absence of significant symptoms.Rhythm diagnosis and management aided by stored electrogram analysis. Circulation . 1993

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部