Long term stability is the main factor that influences the minimum detectable signal of microwave radiometers. Two new types of microwave radiometer were studied: a computer gain compensative microwave radiometer and a real-time calibrated microwave radiometer. The long term stability of both designs was optimal because they were insensitive to system gain fluctuations. The continuous calibrated microwave radiometer was also insensitive to system noise fluctuations. The minimum detectable signals were 0.13 and 0.19K respectively under an integration time of 0.6s.
Long term stability is the main factor that influences the minimum detectable signal of microwave radiometers. Two new types of microwave radiometer were studied: a computer gain compensative microwave radiometer and a real-time calibrated microwave radiometer. The long term stability of both designs was optimal because they were insensitive to system gain fluctuations. The continuous calibrated microwave radiometer was also insensitive to system noise fluctuations. The minimum detectable signals were 0.13 and 0.19K respectively under an integration time of 0.6s.