A suggestion for unification of present limb lead systems into a single“F”lead system

SPECIAL COMMUNICATION A suggestion for unification of present limb lead systems into a single “F” lead system
原文传递
导出
摘要 Abstract In this paper it is intended to unify the standard lead and the augmented unipolar limb lead (aV lead) system into a single lead system. Viewing from the angle of lead axes, the standard leads and the aV leads are not only reflecting the frontal plane vector, but are also actually complementary to each other. By now it has become quite obvious that they not only can, but also should be unified into a single system. Viewing these six leads (from standard lead and aV lead systems), starting from aVL, lead Ⅰ, reversed aVR, lead Ⅱ, aVF to lead Ⅲ, an arc including approximately 150° is formed. It is suggested that this unified system may be called “F” system with each of the above leads renamed as F1 F6 leads, respectively, since they are all reflecting the vectors of the frontal plane. In this F lead system each lead is approximately 30° apart. If such a system would be adopted it is only necessary to time the amplitude of the P, QRS and T of aV lead by 1.15 (a figure calculated by vector analysis). If this suggestion is widely adopted there will be only a F lead system for the frontal vectors and the present V system for the “horizontal” vectors in the electrocardiogram. Abstract In this paper it is intended to unify the standard lead and the augmented unipolar limb lead (aV lead) system into a single lead system. Viewing from the angle of lead axes, the standard leads and the aV leads are not only reflecting the frontal plane vector, but are also actually complementary to each other. By now it has become quite obvious that they not only can, but also should be unified into a single system. Viewing these six leads (from standard lead and aV lead systems), starting from aVL, lead Ⅰ, reversed aVR, lead Ⅱ, aVF to lead Ⅲ, an arc including approximately 150° is formed. It is suggested that this unified system may be called “F” system with each of the above leads renamed as F1 F6 leads, respectively, since they are all reflecting the vectors of the frontal plane. In this F lead system each lead is approximately 30° apart. If such a system would be adopted it is only necessary to time the amplitude of the P, QRS and T of aV lead by 1.15 (a figure calculated by vector analysis). If this suggestion is widely adopted there will be only a F lead system for the frontal vectors and the present V system for the “horizontal” vectors in the electrocardiogram.
作者 黄宛
出处 《Chinese Medical Journal》 SCIE CAS CSCD 1998年第6期85-89,共5页 中华医学杂志(英文版)
关键词 SUGGESTION lead system
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部