期刊文献+

Horizontal platform supported total hip replacement

Horizontal platform supported total hip replacement
原文传递
导出
摘要 Objective To investigate the effect of horizontal platform supported (HPS) prosthesis on cementless total hip replacement for surgical treatment of arthritis in a long-term follow-up study.Methods Clinical and radiographic follow-up of 65 consecutive primary cementless porous coated HPS total hip replacements, which were implanted in 60 patients between 1982 and 1989, was carried out.Results The 53 hips in 50 patients were evaluated both clinically and radiographically. The average follow-up was 6.8 years (range: 5 to 12 years). According to the Harris hip score, 52 (98%) of the hips had sustained an excellent or good result with an average score of 92. At the time of final assessment, no patient experienced anterior thigh pain. There were two revisions performed early in the series due to technical failures. Radiographically, osteolysis and bone re-modelling were assessed. Conclusion The findings suggest that the clinical and radiographic results after cementless total hip replacement for primary hip arthroplasty may be favourably influenced by the use of the proximal stress loaded HPS femoral component. Objective To investigate the effect of horizontal platform supported (HPS) prosthesis on cementless total hip replacement for surgical treatment of arthritis in a long-term follow-up study.Methods Clinical and radiographic follow-up of 65 consecutive primary cementless porous coated HPS total hip replacements, which were implanted in 60 patients between 1982 and 1989, was carried out.Results The 53 hips in 50 patients were evaluated both clinically and radiographically. The average follow-up was 6.8 years (range: 5 to 12 years). According to the Harris hip score, 52 (98%) of the hips had sustained an excellent or good result with an average score of 92. At the time of final assessment, no patient experienced anterior thigh pain. There were two revisions performed early in the series due to technical failures. Radiographically, osteolysis and bone re-modelling were assessed. Conclusion The findings suggest that the clinical and radiographic results after cementless total hip replacement for primary hip arthroplasty may be favourably influenced by the use of the proximal stress loaded HPS femoral component.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 1998年第12期38-42,共5页 中华医学杂志(英文版)
关键词 Hip Prosthesis ADULT Aged Arthroplasty Replacement Hip Female Femur Head Necrosis Follow-Up Studies Humans Male Middle Aged Osteoarthritis Hip OSTEOLYSIS Hip Prosthesis Adult Aged Arthroplasty, Replacement, Hip Female Femur Head Necrosis Follow-Up Studies Humans Male Middle Aged Osteoarthritis, Hip Osteolysis
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部