摘要
10000m^3/h制氧机组粗氩净化系统特别是经除氧后的冷却脱水效果差,使得过冷器和精氩塔因带水发生堵塞,为此,我们对粗氩净化系统进行了多次改造,使运行状况有明显改善。
Because the efficiency of the crude argon purifying system of the No. 1 10000 m3/h oxygen generator, especially the cooling and dewatering efficiency after oxygen removal is poor, the superckkling device and pure argon column are frequently clogged by the water. In order to solve the probems, we have made several technical reformations to the crude argon purifying system and greatly improved their operationg efficienct.
出处
《山西冶金》
CAS
1998年第3期5-7,共3页
Shanxi Metallurgy
关键词
制氧机
氩净化
堵塞
改造
oxygen generator, argon purifying, dogging, reformation