摘要
本文提出了一种在酒石酸铵—氨水体系中用阳极溶出伏安法同时测定高纯铟中痕量杂质铅和镐的新方法,工艺简单而且精密度高。不需预先和基体分离,在一定条件下对高纯铟样品进行测定.测定限铅可达1×10-1%.镉可达1×10-5%、铅、镉平均加标回收率均可达99%以上。
A new method of simultaneous determination for Pb and Cd by anodic solving voltammetry was studied in C4H12N2O6-NH4 OH solution The method has simple technology and high accuracy. It has been used for direct ditermination of Pb and Cd in in samples. The detection limit of Pb and Cd can both reach 1×10-5% o Their recoveries can both reach over 99%.
出处
《渤海大学学报(自然科学版)》
CAS
1998年第4期26-30,共5页
Journal of Bohai University:Natural Science Edition
关键词
铟
阳极溶出伏安法
测定
铅
镉
Indium, anodic solving voltammetry, determination, Lead, Cadmium