期刊文献+

Response mechanism of platinum electrode to uncoupled ions(Ⅰ)——Response of platinum electrode to Pb^(2+),Cd^(2+),Ca^(2+) and Mg^(2+)

Response mechanism of platinum electrode to uncoupled ions(Ⅰ)——Response of platinum electrode to Pb^(2+),Cd^(2+),Ca^(2+) and Mg^(2+)
原文传递
导出
摘要 The transient response mechanism of the platinum electrode to the uncoupled ions may be interpreted with the mixed phase formation (MPF) model of the transient response of precipitate-based ion-selective electrodes to interfering tons for Kxy<<1 It is discovered that the peak height of the transient signal is related to the solubility of M(OH)2 and hydration heat of M2+ The relation between the positive peak height of transient signal of Pb2+ or Cd2+ and lgaM obey tne Nernst equation,while that of Ca2+ or Mg2+ does not.The equilibrium potential is not of Nernst response for all ions. The transient response mechanism of the platinum electrode to the uncoupled ions may be interpreted with the mixed phase formation (MPF) model of the transient response of precipitate-based ion-selective electrodes to interfering tons for Kxy&lt;&lt;1 It is discovered that the peak height of the transient signal is related to the solubility of M(OH)2 and hydration heat of M2+ The relation between the positive peak height of transient signal of Pb2+ or Cd2+ and lgaM obey tne Nernst equation,while that of Ca2+ or Mg2+ does not.The equilibrium potential is not of Nernst response for all ions.
出处 《Science China Chemistry》 SCIE EI CAS 1997年第1期37-44,共8页 中国科学(化学英文版)
基金 supported by the National Natural Science Foundation of China
关键词 PLATINUM ELECTRODE uncoupled ion TRANSIENT potential RESPONSE signal mixed phase formation model platinum electrode,uncoupled ion,transient potential response signal,mixed phase formation model
  • 相关文献

参考文献13

  • 1GAO Hong.Oscillographic Titration. . 1990
  • 2Morf,W. E.Time-dependent selective behavior and dynamic response of silver halide membrane electrodes to interfering ions, Anal. Chemtracts . 1983
  • 3Petrakovich,V. E.Oxidized-platinum electrode in electrometric analysis, Zh.Analit. Khim . 1963
  • 4Dolezal,J.,Stulik,K.The use of platinum and carbon indicator electrode in acid-base titrations. Journal of Electroanalytical Chemistry . 1968
  • 5Antropov L.I.Theoretical Electrochemistry. . 1977
  • 6Dobos D.Electrochemical Data, A Handbook for Electrochemists in industry and Universities. . 1975
  • 7Berube T R Buck R P Lindner E et al.Comparison of proposed response mechanism of precipitate-based ion-selective electrodes in the presence of interfering ions, Anal. Chemtracts . 1989
  • 8Lindner E,Toth K,Pungor E et al.Switched wall Jet for dynamic response measurements. Analytical Chemistry . 1987
  • 9Gratzl M,Lindner E,Pungor E.Theoretical interpretation of transient signsals obtained with precipitate-based ion-selective electrodes in the presence of interfering ions. Analytical Chemistry . 1985
  • 10Lewenstam A,Hulanicki A,Sokalski T.Response mechanism of solid-state ion-selective electrodes in the presence of interfering ions. Analytical Chemistry . 1987

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部