期刊文献+

VALVE REPLACEMENT WITH BILEAFLET HEART VALVE PROSTHESIS: FOLLOW-UP OF 170 CASES

VALVE REPLACEMENT WITH BILEAFLET HEART VALVE PROSTHESIS: FOLLOW-UP OF 170 CASES
下载PDF
导出
摘要 From Feb. 1989 to May 1996, 170 patients underwent valve replacement with bileaflet heart valve prosthesis. There were 13 early deaths (mortality of 7-65% ), and 6 late deaths. The Preoperative cardiac function (NYHA) was grade Ⅱ in 96 cases, Ⅳ in 35 cases and Ⅲ to Ⅳ in 77. 1%.Follow-up of the survivors from 3 to 87 (average 39) months showed that most of them could do light and moderate physical labor, and cardiac function was restored to grade Ⅰ~ Ⅱ in 96. 4%. Anti-coagulating bleeding is a common complicaion. However, severe embolism and valve dysfunction had not been found- The authors analysed the causes of death and follow-up data, then emphasized that it was necessary that valve replacement be performed as early as possible, and bileaflet heart valve substitute was the best choice. Furthermore, therapy of little dose anti-coagulating drug(warfarin 1.5~3- 0mg/d) is safe and dependable to most of the patients. From Feb. 1989 to May 1996, 170 patients underwent valve replacement with bileaflet heart valve prosthesis. There were 13 early deaths (mortality of 7-65% ), and 6 late deaths. The Preoperative cardiac function (NYHA) was grade Ⅱ in 96 cases, Ⅳ in 35 cases and Ⅲ to Ⅳ in 77. 1%.Follow-up of the survivors from 3 to 87 (average 39) months showed that most of them could do light and moderate physical labor, and cardiac function was restored to grade Ⅰ~ Ⅱ in 96. 4%. Anti-coagulating bleeding is a common complicaion. However, severe embolism and valve dysfunction had not been found- The authors analysed the causes of death and follow-up data, then emphasized that it was necessary that valve replacement be performed as early as possible, and bileaflet heart valve substitute was the best choice. Furthermore, therapy of little dose anti-coagulating drug(warfarin 1.5~3- 0mg/d) is safe and dependable to most of the patients.
出处 《Journal of Pharmaceutical Analysis》 CAS 1997年第1期66-69,73,共5页 药物分析学报(英文版)
关键词 Bileaflet heart valve prosthesis valve replacement HEMODYNAMICS Bileaflet heart valve prosthesis valve replacement hemodynamics
  • 相关文献

参考文献7

  • 1徐志云,张宝仁,朱家麟,郝家骅,陈如坤,蔡用之.国产侧倾碟瓣二尖瓣替换10年以上随访[J].中华胸心血管外科杂志,1995,11(3):135-137. 被引量:36
  • 2Arom KV,Nicoloff DM,Kersten TE,et al.Ten-year followup study of patients who had double valve replacement with the St.JudeMedical Prothesis. Journal of Thoracic and Cardiovascular Surgery . 1989
  • 3Katz AM.Cardiomyopathy of overload: A major determinant of prognosis in congestiveheart failure. The New England Journal of Medicine . 1990
  • 4Izzat MB,Birdi I,Wilder P,et al.Comparison of hemodynamic performances of SJM andCM 21 mm aortic prostheses by means ofdobutamine stress echocardiography. Journal of Thoracic and Cardiovascular Surgery . 1996
  • 5Depaulis R,Sommariva L,Russo F,et al.Doppler echocardiography evaluation of theCM valve in patients with samll aortica annulus and valve prosthesis-body surface aresmismatch. Journal of Thoracic and Cardiovascular Surgery . 1994
  • 6Alvarez L.Late sudden cardiac death in thefollow-up of patients having a heart valveprosthesis. Journal of Thoracic and Cardiovascular Surgery . 1992
  • 7Khan S,Chaux A,Matloff J et al.The St.Jude Medical valve: experience with 1000 cases. Journal of Thoracic and Cardiovascular Surgery . 1994