摘要
介绍了跟踪式热平衡温度测量的原理:当检测头与被测体靠近时,通过对流换热形成梯度为零的温度场,因而二者温度相等。这种梯度为零的温度场是通过对检测头的一端制冷(或加热)跟踪被测体的温度形成的.最后给出了静态和动态实验的测试结果。
This paper introduces the principle of temperature measurement by themethod of tracking type heat banlance. When a detecting headis close to a measured object,auniform temperature field with no gradient will form through heat convection. Therefore,their temperature is equal.The uniform temperature field with no gradient is formed by re-frigerating(or heating)one side of the detecting head,and tracking the temperature ofmeqsured object.To end with,the static and dynamic test results are given.
出处
《沈阳理工大学学报》
CAS
1995年第4期63-68,共6页
Journal of Shenyang Ligong University
关键词
温度测量
热平衡
跟踪
对流换热
热泵
temperature measurement, heat balance,tracking,heat convection,heat pumps.