摘要
本文研究了在具有支撑墙的蓄热室底部设置对称的简单挡墙及梯形挡墙,以改善蓄热室内的气流分布的均匀性。对设置上述二种挡墙的影响因素如简单挡墙的高、宽,安装位置;梯形挡墙的倾角、墙高、墙间距离等展开研究,分别确定了两种挡墙的最佳方案。
In this paper the research result on modifying airflow distribution in tlie regenera-tive chamber with supporting wall by the baffle and ladder-shaped baffle set up on the bottom of the chamber is repOrted.Meanwhile, some major influence factors which affect the action efficacy of the two baffles, such as the height, the width of the baffles as well as the place where the baffles are put up, the height, the distance between baffles, the inclination of the ladder-shaped baffles, are given a minute description besides, on the basis of the research achievement, an optimum plan on installing the two baffles are determined
出处
《玻璃》
1995年第2期4-10,共7页
Glass