摘要 目的探讨准分子激光角膜切削术后角膜厚度的变化。方法采用Tomey,SP—2000型角膜超声测厚仪测量PRK术前及术后1月、3月及6月的角膜厚度。结果角膜厚度1月与3月、6月之间有显著差异,3月与6月之间无显著差异,A、B两组间术后1月、3月有显著差异,6月无显著差异。结论PRK术后角膜厚度在3个月时趋于稳定,术前屈光度的高低与术后角膜厚度的大小无关。 Observer the change of corneal pachymetry post excimer laser photorefractive keratectomy (PRK).Methods Used Tomey. SP-2000 ultrasonic machine to measure the corneal thickness before and after PRK. Results The corneal pachymetry at 1 and 3 month was ofstatistically significant differences,and the same at 1 and 6 month. but at 3 and 6 month was not so. Group A and Group B at 1,3 month was of statistically significant differences,and was not of at 6 month. Conclusion The corneal thickness was stability at 3 month after PRK. The refractive power before PRK was not relation with the cornealpachymetry after PRK.
出处 《临床眼科杂志》 1998年第1期14-15,共2页 Journal of Clinical Ophthalmology
关键词 准分子激光 屈光度 角膜厚度 角膜切削术 Excimer laser Refrative Corneal pachymetry
  • 相关文献

参考文献2

二级参考文献1

共引文献30

同被引文献32

  • 1李海燕,孙同,李莹,金玉梅,胡明,孙传宾.不同品牌准分子激光机对角膜切削深度的比较[J].中外医疗,2007(18):43-44. 被引量:10
  • 2李凯,王育良,王跃静.LASIK角膜瓣蒂位置对术后干眼症发病率的影响[J].眼科,2003,12(6):330-332. 被引量:12
  • 3庞辰久,宋晓虹,张黎,张英朗,王丽娅.Technolas 217z准分子激光角膜组织切削深度预测性的评价[J].中国实用眼科杂志,2007,25(3):320-323. 被引量:7
  • 4陈兵,王勤美.LASIK术中颞侧角膜蒂的观察[J].眼外伤职业眼病杂志,2007,29(2):111-113. 被引量:2
  • 5Feltham MH, Stapleton F. Change in central corneal thickness following laser in situ keratomileusis for myopia[ J ]. Clin Exp Ophthalmol,2000,28 ( 3 ) : 185 -187.
  • 6Kozak I, Hornak M, Juhas T, Shah A, Rawlings EF. Changes in central corneal thickness after laser in situ keratomileusis and photorefractive keratectomy [ J ]. J Refract Surg, 2003,19 ( 2 ) : 149-153.
  • 7Chen S, Feng Y, Stojanovic A, Jankov MR, Wang Q. IntraLase femtosecond laser vs mechanical microkeratomes in LASIK for myopia: a systematic review and meta-analysis [ J ]. J Refract Surg,2012,28 ( 1 ) : 15-24.
  • 8Sekundo W, Kunert KS, Blum M. Small incision corneal refrac- tive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic a- stigmatism:results of a 6 month prospective study [J]. Br J Ophthalmo1,2011,95 ( 3 ) :335-339.
  • 9Vestergaard A, Ivarsen AR, Asp S, Hjortdal JO. Sman-incision lenticule extraction for moderate to high myopia: Predictability, safety,and patient satisfaction[J]. J Cataract Refract Surg, 2012,38 ( 11 ) :2003-2010.
  • 10Iskander NG ,Anderson Penno E, Peters NT, Gimbel HV, Feren- sowicz M. Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomile- usis and LASIK enhancement procedures[J].J Cataract Refract Surg, 2001,27 ( 5 ) : 681-685.