期刊文献+

输精管管腔测量器的研制及应用 被引量:2

AN APPARATUS FOR THE MEASUREMENT OF INTERNAL DIAMETER OF SPERMATIC DUCT IN VIVO
原文传递
导出
摘要 本文介绍自行研制的活体输精管腔测量器。经动物和人体输精管腔测量验证误差值均为0.03±0.05mm,管腔测量后还可进行注射节育。对生育期男性200人,400根输精管测量结果为扩张状态下输精管内径值为1.25±0.02mm。对兔输精管的管腔进行可扩张性试验表明:用堵塞材料将管腔容积扩张7倍,为最小有效堵塞管腔值。用该值在测量器指导下作注射栓堵法绝育术200例,比对照组根据手触摸输精管粗细所用的堵塞量明显减少,而节育效果两组十分近似,并且术后不适反应发生率比对照组明显减少。 An apparatus for measurement of internal diameter of spermatic duct was introduced.Two hundreds male adults(400 ducts)were tested.The average internal diameter was 1.25±0.02 mm in dilated condition.Expandible test for internal cavity of vas showed that the minimal effective volume for cavity blocking was seven folds of the original volume.The blocking agents used in vasal sterility accordig to this measurement is smaller than that by palpation with hand,and the sterilization effect is same.
出处 《中国男科学杂志》 CAS CSCD 1989年第2期98-101,共4页 Chinese Journal of Andrology
关键词 输精管腔 测量器 Vas deferens Measurator
  • 相关文献

同被引文献11

  • 1陈振文,谷翊群,梁小薇,沈立军,邹万忠.聚氨酯栓堵局部输精管的形态学观察[J].生殖医学杂志,1994,3(1):26-26. 被引量:4
  • 2赵生才.输精管可复性注射栓堵法研究[J].生殖与避孕,1986,6:12-12.
  • 3黄明孔,李国柱,邹平,蔡学澄,彭德先,潘慈康,裴容生.输精管结扎术后精液中残余精子的能动期、生存期和存在期[J]男性学杂志,1988(02).
  • 4Zhao SC.Vas deferens occlusion by percutaneous injection of polyuertehane elastomer plugs, clinical experince and reversibility, pontraception. . 1990
  • 5WHO.Aborat human semen and semen-cervical mucus interaction. . 1987
  • 6Mann T.The biochemistry of semen and male reproductive tract. . 1964
  • 7陈胜民,曹泽贵,周恒毅,谢鑫运,李必寿,单福周,向前.700例正常健康男子输精管测量[J]生殖与避孕,1988(01).
  • 8赵生才.输精管可复性注射栓堵法研究[J]生殖与避孕,1986(01).
  • 9李顺强,黄明孔,朱金波.输精管注射绝育研究(附临床应用七年的随访报告)[J]生殖与避孕,1980(01).
  • 10吕延鹤,杨凤升,樊云井,黄真嘉.输精管可复性注射栓堵后并发症47例临床分析[J].男性学杂志,1991,5(4):219-221. 被引量:9