摘要
通过探索,用ABEI发光剂标记人CuZn-SOD,液相竞争结合测定样品中CuZn-SOD含量。本方法试剂稳定,结果重复性好,批内CV=2.6~6.0%,批间CV=6.9~7.9%,回收率97.7~106.1%,可测范围为1~500ng,适合测定血清及体液中微量CuZn-SOD。本化学发光免疫分析为国内外尚未报道的方法。
The human CuZn-SOD labelled with 6[N-(4-aminobutyl)-N-ethyl]-isoluminol (ABEl) has een used for estimating total CuZn-SOD, and then a new method of chemiluminescent immunoassay as established. Inter-assay coefficients of variation were 2.6—6.0% and 6.9—7.9% espectively. The recoveries of human CuZn-SOD added in sample were 97.7—106.1%. The assay as roved to be reliable, accurate and the limit of determination was 1—500 ng. The method has een successfully applied in the determination of total CuZn-SOD content in serum or xtracellular fluids.
出处
《解放军医学院学报》
CAS
1989年第2期150-152,共3页
Academic Journal of Chinese PLA Medical School