摘要
目的探讨改良日出位X线片在评估后交叉韧带(PCL)损伤中的应用价值。方法对43例确诊为单纯PCL损伤的患者摄取改良日出位X线片,在X线片上对双膝胫骨平台前缘相对于股骨髁前缘距离进行测量和对比,计算其差值即PCL损伤膝胫骨近端后移位值,然后进行关节镜检查排除合并前交叉韧带损伤(ACL),并进行PCL部分断裂和完全断裂的甄别诊断和分组记录,对改良日出位X线片测量结果进行统计比较。结果其中PCL不完全断裂19例,胫骨平台向后移位的平均值是(6.2±1.9)mm;PCL完全断裂24例,胫骨平台向后移位平均值是(11.8±2.3)mm;前后平均值比较,P<0.01。结论膝关节改良日出位X线片在PCL损伤的检查和诊断中有优越的实用价值。该方法操作简单,结果准确可靠,可重复性强,经济实用,可作为PCL损伤的常规检查方法和重要诊断依据。
Objective To discuss the value of stress radiography using the modified sunrise view technique with the knee in the diagnosis of posterior cruciate ligament (PCL) injury. Methods Forty-three patients with simple and unilateral PCL injury were enrolled in stress radiography using the modified sunrise view technique with the knee. The quantity of posterior tibia/subluxation in knees with PCL ruptures was measured by the radiograph.Results In knees with complete PCL ruptures (24 patients), the mean posterior tibial subluxation increase was (11.8±2.3) mm while in knees with part PCL ruptures (19 patients), the mean posterior tibial subluxafion increase was (6.2±1.9) ram, P〈0.01. Conclusion Modified sunrise view technique with the knee for the diagnosis of PCL injury is practical and the technique is easy to grasp with the accurate results and high repeatability.
出处
《中国骨与关节损伤杂志》
2009年第4期292-294,共3页
Chinese Journal of Bone and Joint Injury