摘要 建立了HPLC法测定人血浆中的米格列奈。以地西泮为内标,采用C18色谱柱,20mmol/L磷酸二氢钾溶液(pH4.6)-乙腈(57∶43)为流动相,检测波长210nm。米格列奈钙在25~8000ng/ml范围内线性关系良好。方法回收率为98.1%~109.2%,批内、批间RSD为1.5%~13.4%。 An HPLC method was established for the determination of mitiglinide in human plasma. Diazepam was used as the internal standard. A C18 column was used with the mobile phase of 20 mmol/L potassium dihydrogen phosphate (pH 4.6)-acetonitrile (57 : 43)at the detection wavelength of 210 nm. The calibration curve was linear in the concentration range of 25 - 8 000 ng/ml. The recoveries were between 98.1% - 109.2 % with intra- and inter-run RSDs of 1.5% - 13.4%.
出处 《中国医药工业杂志》 CAS CSCD 北大核心 2009年第4期283-285,共3页 Chinese Journal of Pharmaceuticals
关键词 米格列奈 高效液相色谱 测定 mitiglinide HPLC determination
  • 相关文献

参考文献3

  • 1Liang JB, Tian Y, Zhang ZJ. High-performance liquid chromatography-electrospray ionization mass spectrometry determination of mitiglinide in human plasma and its pharmacokinetics[J].J Mass Spectrom, 2007, 42 (2): 171-177.
  • 2Yu L, Zeng S. Determination of mitiglinide in rat plasma by high-performance liquid chromatography with UV detection [J]. J Chromatogr B, 2006, 834 (1-2) : 204-207.
  • 3Zhou L J, Gu LH, Wang YJ, et al. Determination of bifendate in human plasma by HPLC-MS and bioequivalence on bifendate pills in healthy volunteers [J]. J Pharm Biomed Anal, 2006, 40 (4) : 1025-1030.