期刊文献+

B-Z振荡反应在VitB_1含量测定中的应用 被引量:2

Application of B-Z Oscillating Reaction in Determination on Content of VitB_1
下载PDF
导出
摘要 应用B-Z振荡反应测定VitB1的含量,并研究不同浓度VitB1对该振荡体系的影响。结果表明,在0.0007~0.0015 mol/L范围内,VitB1浓度C与B-Z振荡体系的周期改变值Δtp呈良好的线性关系。B-Z振荡体系用于测定VitB1含量具有选择性、重复性好和灵敏度高等优点。 Utilize B-Z oscillating reaction was used to measure the content of VitB1,and the effects of VitB1 with different concn.on the oscillation system were studied.The results showed in 0.000 7-0.001 5 mol/L,the concn.of VitB1 C and cycle change value Δtp of B-Z oscillation system had good linear relationship.Using B-Z oscillation system to determine the content of VitB1 had good selectivity and repeatability with high sensitivity.
出处 《安徽农业科学》 CAS 北大核心 2009年第9期3880-3881,共2页 Journal of Anhui Agricultural Sciences
基金 广西自然科学基金项目[桂科自(0728227)] 广西教育科学"十五"规划项目(C046)
关键词 B-Z振荡体系 VITB1 含量 测定 B-Z oscillation system VitB1 Content Measuring
  • 相关文献

参考文献3

  • 1范少华,安从俊,庄林,甘南琴,林智信.维生素B_1对B-Z振荡反应的影响及反应动力学[J].物理化学学报,1999,15(2):178-181. 被引量:38
  • 2FIELD R J,DOROS E, NOYES R M.Oscillations in chernical systems.II.Thorough analysis of temporal oscillation in the bromate-cerium-malonic acid system [J]. Chem. Soc., 1972,94:8649 - 8664.
  • 3黄厚评 蔡汝秀.痕量分析[J].化学通报,1972,8(2):40-44.

二级参考文献2

共引文献37

同被引文献41

引证文献2

二级引证文献14