期刊文献+

牙用镍铬合金表面不同涂层抗腐蚀性研究 被引量:1

The contrastive reserch on the corrosion resistance of Ni-Cr alloy with different coatings
原文传递
导出
摘要 目的:探讨镍铬合金表面不同涂镀层的抗腐蚀性能。方法:将4种涂镀层镍铬合金试件,分别浸泡在中性人工唾液2个月、酸性人工唾液20d。结果:在中性和酸性人工唾液中,镍铬合金表面涂镀的氮化钛膜、电镀金膜、金泥涂层及金瓷涂层,都表现出良好的耐腐蚀性能。结论:在相同的人工唾液环境中,不含铍镍铬合金比含铍镍铬合金具有更佳的耐腐蚀性能。 Objective: Doing contrastive research on corrosion resistance of Ni-Cr alloy with different coatings. Method: The corrosion resistance of the Ni-Cr alloy with the four coatings were qualitatively and quantitatively studied by immersing into the natural artificial saliva two months and acidic artificial saliva twenty days. Result: Titanium nitride (TIN) film, gold electroplating layer, gold paste and gold-ceramic compound showed good corrosion resistance.Conclusion:The corrosion resistance of Ni-Cr alloy Ⅰ is more than Ni-Cr alloy Ⅱ in the natura and acidic artificial saliva.
出处 《临床口腔医学杂志》 2009年第4期223-225,共3页 Journal of Clinical Stomatology
关键词 镍铬合金 抗腐蚀 Ni-Cr alloy corrosion resistance
  • 相关文献

参考文献7

  • 1Wataha J C. Biocompatibility of dental casting alloys: A review [J]. J Prosthet Dent, 2000, 83 (2) : 223-234.
  • 2Hendry J A, Pilliar R M. The fretting corrosion resistance of PVD surface-modified orthopedic implant alloys [J]. J Biomed Mater Res, 2001,58 (2) : 56-66.
  • 3Hai K, Sawase T, Matsumura H, et al. Corrosion resistance of a magnetic stainless steel ion-plated with titanium nitride [J]. Journal of oral rehabilitation, 2000, 27 (4) : 361-366.
  • 4Starosvetsky D, Gotman 1. Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy [J']. Biomaterials, 2001,22 (13) : 1853-9.
  • 5朱松,刘红,陈晓梅,孙宏晨.烤瓷用镍铬合金经不同预处理的表面氧化膜研究[J].口腔医学研究,2005,21(3):253-255. 被引量:5
  • 6胡滨,张富强.表面涂层技术对镍铬合金耐蚀性能的影响[J].上海口腔医学,2003,12(2):132-135. 被引量:17
  • 7Wataha J C. Principles of biocompatibility for dental practitioners[J]. J Prosthet Dent,2001,86(2):203-209.

二级参考文献17

  • 1文志红,杜传诗,巢永烈,郑弟泽.除气和预氧化对金-瓷结合强度的影响[J].华西口腔医学杂志,1996,14(1):10-12. 被引量:18
  • 2Wataha JC, Lockwood PE, Khajotia SS, et al. Effect of pH on element release from dental casting alloys [J]. J Prosthet Dent, 1998, 80: 691-698.
  • 3Aziz-Kerrzo M, Conroy KG, Fenelon AM, et al. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials[J]. Biomaterials, 2001, 22:1531-1539.
  • 4Jorgenson DS, Centeno JA, Mayer MH, et al. Biologic response to passive dissolution of titanium craniofacial microplates [J].Biomaterials, 1999,20: 675-682.
  • 5Bumgardner JD, Lucas LC. Corrosion and cell culture evaluation of nickel-chromium dental casting alloys[J]. J Appl Biobater, 1994,5: 203-213.
  • 6Wataha JC. Principles of biocompatibility for dental practitioners[J]. J Prosthet Dent, 2001, 86: 203-209.
  • 7Wataha JC, Malcolm CT. Effect of alloy surface composition on release of element from dental casting alloys [J]. J Oral Rebabil, 1996, 23: 583-589.
  • 8Messer RLW, Lucas LC. Cytotoxicity evaluations of ions released from nickel-chromium dental alloys[J]. J Dent Res, 1996, 75: 225.
  • 9Watanabe I, Hai K, Tanaka Y, et al. In vitro corrosion behavior of cast iron-platinium magnetic alloys [J]. Dent Mater, 2001, 17:217-220.
  • 10Wu Y,Moser JB,Jameson LM,et al.The effent of oxidation heat treatment on porcelain bond strength in selected base metal alloys [J].J Prosthet Dent,1991,66(4):439-444.

共引文献20

同被引文献6

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部