摘要
作者对结构设计中一些规范不太明确的问题,如什么是短肢剪力墙较多、地震等级与地震烈度的关系、如何对抗震设防区预制板楼盖加强其整体性等问题,查阅和分析了现有的资料,并提出了自己的看法,可供同行参考。
In this paper, the structural design of some norms not specific questions, such as short-pier shear wall What is more, the intensity of earthquakes and seismic Level of the relations, how to pre-seismic Floor Area covered issues such as strengthening its integrity, inspection and analysis of existing data, and put forward their own views for peer reference.
出处
《中国勘察设计》
2009年第4期61-64,共4页
China Engineering Consulting
关键词
短肢剪力墙
地震等级
地震烈度
预制楼板整体性
现浇混凝土坡层面
short pier shear wall
level seismic
seismic intensity
precast slab integrity
cast-in-place concrete slope level