摘要 目的研制一种适合于大批量室内和环境空气中二氧化氮气体(NO2)现场采样的固相气体采样管。方法固相NO2气体采样管由两端套有硅胶塞玻璃管及其内部填充经过改性的聚丙烯纤维丝束并涂布NO2吸收液,作为固相填充物的载体而组成。建立固相NO2气体采样管对NO2的采样方法。采用改进的Saltzman法(国标法)评价其性能。结果固相NO2气体采样管法的洗脱效率和采集效率≥(99.68±5.45)%和(97.29±0.83)%;该法测定低(0.11 mg/m3)、中(0.46 mg/m3)、高3(0.85 mg/m3)3种不同质量浓度的NO2气体并与国标法比较,两者测定结果分别相差9.10%、4.35%和3.53%,2种方法测定结果差异无显著性(P>0.05)。结论研制的固相NO2气体采样管可用于大规模环境和室内空气中NO2的现场采样。 Objective To develop a kind of solid phase absorbent sampling tube suited to a large number of sampling and analysis for indoor and ambient air NO2. Methods This solid phase absorption gas sampler was consisted of two parts: a glass tube covered with silica - gel plugs as a support part; surface denatured polypropylene fibre in glass tube coated with absorbing solution for NO2 as an absorbent part. Then a method for sampling NO2 was established by this sampler. Modified Sahzman method was adopted to test its function. Results The collection rate and the elution rate of solid phase absorbent sampler were greater than (99.68 ± 5.45) % and (97.29 ±0.83) % respectively. The determination results showed that there were 9.10% ,4.35% ,3.53% differences in low (0.11 mg/m3) , middle(0.46 mg/m3, high (0.85 mg/m3) three levels of NO2 between this method and modified Sahzman method , but which were not statistically significant ( P 〉 0.05). Conclusion This solid phase sampling tube can be used for the field sampling of NO2 in indoor and ambient air.
出处 《解放军预防医学杂志》 CAS 2009年第2期100-103,共4页 Journal of Preventive Medicine of Chinese People's Liberation Army
基金 国家支撑计划(No.2006BA510136)
关键词 固相气体采样管 二氧化氮 室内空气 环境空气 solid phase sampling tube for gas nitrogen dioxide indoor air ambient air
  • 相关文献

参考文献10

  • 1张予燕,张群,薛光璞.南京地区空气NO_2与O_3污染分析[J].江苏环境科技,2007,20(A02):20-22. 被引量:7
  • 2CHEN X, ONO Y, TANAKA K, et al. A New Method for A mospheric Nitrogen Dioxide Measurements Using the Combination of a Stripping Coil and Fluorescence Detection [J]. Analytical Sciences,2004,20(7) :1019.
  • 3TAKETANI F, KAWAI M,TAKAHASHI K, et al. Trace detection of atmospheric NO2 by laser-induced fluorescence using a GaN diode laser and a diode-pumped YAG laser[J]. Appl Opt,2007,46(6):907.
  • 4SHORT L C, FREY R, BENTER T. Simultaneous measurement of nitric oxide (NO) and nitrogen dioxide (NO2) in simulated automobile exhaust using medium pressure ionization-mass spectrometry [J]. Appl Spectrosc, 2006, 60 (2) : 208.
  • 5罗曦芸,刘洪来.固体主动采样法用于检测博物馆内二氧化氮[J].文物保护与考古科学,2004,16(4):11-16. 被引量:3
  • 6中国国家标准化管理委员会.GB/T12372-1990居住区大气中二氧化氮检验标准方法改进的Saltunan法[S].北京:中国标准出版社,1990.
  • 7ISHIGURO G, KAWABE T, NAKA N ,et al. Development of a Detection Tablet for a Portable NO2 Monitoring System [J].Analytical Sciences,2006,22(5) :789.
  • 8TANG Y S, CAPE J N, SUITON M A. Development and types of passive samplers for monitoring atmospheric NO2 and NH3 concentrations [J]. Scientific World Journal, 2001,9 (1):513.
  • 9OZDEN O, DOGEROGLU T. Field evaluation of a tailor- made new passive sampler for the determination of NO2 levels in ambient air [J]. Environ Monit Assess, 2008, 142 ( 3 ) : 243.
  • 10曹远虑,葛明桥,李永贵.无机粒子处理烟用聚丙烯纤维的吸附性能[J].合成纤维,2006,35(7):4-6. 被引量:5

二级参考文献16

共引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部