循环泵电动机保护零线上反常大电流的故障分析

Fault Analysis on the Abnormally Large Current on the Protection Zero Line of the Circulatory Pump Motor
下载PDF
导出
摘要 阐述了循环泵电动机在试运行中出现异常声音及保护零线上的反常大电流的故障现象,从现场测量、空载试验,以及拆卸后的检测情况,对电动机的故障原因进行了深层次的分析,说明对故障要做全面的分析,注意避免思维定势。对专业技术人员解决现场实际问题具有一定的指导意义。 This paper describes the fault phenomenon which includes the unusual sound and abnormally large current on the protection zero line during the pilot operation of the circulatory pump motor, profoundly analyzes the fault causes of the motor in the respects of onsite measurement, free load test and inspection situation after disassembly, so as to demonstrate that the comprehensive analysis on the fault should be done and the stereotype of thinking should be avoided. It has guiding significance for the professionals to handle the actual problems on site
出处 《供用电》 2009年第2期44-45,共2页 Distribution & Utilization
关键词 循环泵电动机 保护零线 反常大电流 空载试验 circulatory pump motor protection zero line abnormally large current free load tests