摘要 为了达到最佳的扩束效果和充分利用束流,从多次库仑散射角、能量损失和透射率这三个方面确定扩束器的材料类型。对均方根多次库仑散射(MCS)、质子能量损失和质子的透过率的研究都表明单位面质量下材料原子序数越大,扩束效果越好。再结合成本和适用性确定扩束器的材料为钨。同时,从探测器接收到的质子通量均匀而噪声影响小的角度,确定了扩束器的厚度。研究结果为:没有准直器的情形下,扩束器的厚度为3.1cm;准直器角度为3.0mrad时,扩束器厚度为2.4cm。 In order to achieve the best expanding effeciency of the diffuser and to use most protons to radiate the French Test Object, the material is chosed from three aspects. They are MCS (multiple Coulomb scattering) angle, energy loss and penetration rate for proton per unit areal mass. The analyzed results of these aspects show that the bigger the atomic number is, the high- er the efficiency is. The material is determined to be tungsten considering cost and applicability. The thickness of the diffuser is designed according to the demands of uniform proton flux distribution and small noise. As a result, the diffuser thicknesses are 3.1 cm without collimator and 2.4 cm with 3.0 mrad collimator,
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2009年第3期455-458,共4页 High Power Laser and Particle Beams
基金 国防技术基础研究基金资助课题
关键词 质子照相 FTO客体 扩束器 准直器 proton radiography French Test Object diffuser collimator
  • 相关文献

参考文献10

  • 1Amann J F, Espinoza C J, Gomez J J,et al. High-energy test of proton radiography concepts[R]. LA-UR-97-1520,1997.
  • 2Scarpetti R D, Nath S, Barraza J, et al. Status of the DARHT 2nd axis accelerator at the Los Alamos National Laboratory[C]//Proceedings of the 2007 Particle Accelerator Conference. 2007.
  • 3Ziock H J, Adams K J, Alrick K R, et al. The proton radiography concept[R]. LA-UR-98-1368, 1998.
  • 4许海波.高能质子照相中面密度的测量和不确定性分析[J].强激光与粒子束,2006,18(3):477-482. 被引量:10
  • 5Lynch G R, Dahl O I. Approximations to multiple Coulomb scattering[J]. Nucl Instrum Meth Phys Res B ,1991,58:6-10.
  • 6Tsai Y S. Pair production and Bremsstrahlung of charged leptons[J]. RevMod Phys ,1974,46:815.
  • 7Groom D. Energy loss in matter by heavy particles[Z]. Particle Data Group Note PDG-93-06,1993.
  • 8Letaw J R, Silberberg R, Tsao C H. Proton-nucleus total inelastic cross sections: an empirical formula for E greater than 10 MeV[J]. The Astrophysical Journal, 1983 ,s51 : 271-276.
  • 9Mottershead C T, Zumbro D. Magnetic optics for proton radiography[C]//Proceedings of 1997 Particle Accelerator Conference, 1997.
  • 10Neri F, Thiessen H A, Walstrom P L, et al. Synchrotrons and beamlines for proton radiography[C]// Proceedings of 1997 Particle Accelerator Conference. 1997.

二级参考文献15

  • 1Boyd T J.A pulsed high-energy radiographic machine emitting X-rays[R].LA-3241,1967.
  • 2Burns M J,Carlston B E,Kwan T J T,et al.Durht accelerators update and plans for initial operation[C]//Proceedings of 1999 Particle Accelerator Conference.1999,1:617-621.
  • 3Schneider U,Pedroni E.Proton radiography as a tool for quality control in proton therapy[J].Medical Physics,1995,22(4):353-363.
  • 4Morris C L.Proton radiography for an advanced hydrotest facility[R].LA-UR-00-5716,2000.
  • 5Meitzner G D,Fischer D A.Distortions of fluorescence yield X-ray absorption spectra due to sample thickness[J].Microchemical Journal,2002,71(2):281-286.
  • 6Schneider U,Pedroni E.Multiple coulomb scattering and spatial resolution in proton radiography[J].Medical Physics,1994,21(11):1657-1663.
  • 7Cunningham G S,Morris C L.The development of flash radiography[R].Los Alamos Science,2003.
  • 8King N S P,Ables E,Alrick K R,et al.An 800-MeV proton radiographic facility for dynamic experiments[J].Nuclear Instruments and Methods in physics research A,1999,424(1):84-91.
  • 9Kwan T J T,Mathews A R,Christenson P J,et al.Integrated system simulation in X-ray radiography[R].LA-UR-01-0071,2001.
  • 10Amann J F,Espinoza C J,Gomez J J,et al.High-energy test of proton radiography concepts[R].LA-UR-97-4721,1997.

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部