摘要
分析了京能热电化学水处理系统自用水偏高的原因,对各水处理设备进行了调试,努力降低水处理设备的自用水率,并加强运行指标的调整和控制,维持在自用水率低的工况下运行,同时也降低了化学水处理药剂的消耗,减少了酸碱对环境的污染,具有很好的社会和经济效益。
This paper analyses the causes of high consumption rate of self-using water for chemistry water treatment system of Beijing Jingneng Thermal Power Co. Ltd. , The water treatment devices were adjusted so as to reduce the self-using water ratie of water treatment equipment. Through adjustment and control of operating indexes, the water treatment system is maintaining low consumption rate of self-using water, meanwhile the chemicals added is reduced. It also reduced the impact of acid and alkaline on environment. It brought about good social and economic benefit.
出处
《华北电力技术》
CAS
2009年第4期51-54,共4页
North China Electric Power
关键词
水处理
过滤
制水
再生
自用水
water treatment
filtration
water preparation
reclaimed
self-using water