摘要 目前DGA在线监测系统还存在着元件性能不稳定、抗干扰性能较差、抗外界因素如温度、湿度变化的能力差,造成故障气体的增长性误差比较大,测量数据不稳定等问题。文章利用最小二乘法对误差进行处理,结果显示优化后的数据平稳,可靠性提高。 Currently, in the DGA on-line monitor system some problem still exist, such as unsteady component function, worse anti-interference function, poor anti-environment factor (such as the variety temperature and humidity) ability, big accumulative error of fault, unsteady measurement data. The article makes use of least squares algorithm to deal with the error Results show that the optimization data is steady, and reliability is improved.
作者 张卫国
出处 《船电技术》 2009年第4期43-45,共3页 Marine Electric & Electronic Engineering
关键词 DGA 检测误差 状态监测 最小二乘法 DGA error on-line monitoring least squares algorithm
  • 相关文献

参考文献3

  • 1A. Mollmann and B. Pahlavanpour. New guidelines for interpretation of dissolved gas analysis in oil-filled transformers[J]. Electra, 1999.No. 186, pp. 30-51.
  • 2Guangchun Zhang, Guangning Wu, Dae-Hee Park. Progress of Insulation On-fine Monitoring and Fault Diagnosis Techniques for High Voltage Power Equipment in China[C]. KIEE International Transactions on Electrophsics and Applications, 2002, Vol. 12C(1), pp. 1-14.
  • 3张冠军,钱政,严璋.DGA技术在电力变压器绝缘故障诊断中的应用与进展[J].变压器,1999,36(1):30-34. 被引量:37