期刊文献+

电容层析成像在高压浓相煤粉气力输送中的应用 被引量:12

Application of electrical capacitance tomography in dense-phase pneumatic conveying of pulverized coal under high pressure
下载PDF
导出
摘要 Electrical capacitance tomography (ECT) was applied to dense-phase pneumatic conveying of pulverized coal, including the visualization of gas-solid flows in a horizontal pipeline.The pressure of experimental setup was up to 4.0 MPa, the solid-gas ratio was up to 11.73 kg·kg-1, and the diameter of conveying pipeline was 10 mm.The pipeline thickness of 8-electrode ECT system was 5 mm.An improved AC-based capacitance measuring circuit was developed.Single channel capacitance measuring circuit was adopted to simplify the ECT hardware.Landweber algorithm was used to reconstruct image.The flow characteristics of dense-phase pneumatic conveying was investigated with the method of ECT experiment.Finally, the serial ECT image was compared with the result of Fluent simulation to validate the reliability. Electrical capacitance tomography (ECT) was applied to dense-phase pneumatic conveying of pulverized coal, including the visualization of gas-solid flows in a horizontal pipeline. The pressure of experimental setup was up to 4.0 MPa, the solid-gas ratio was up to 11.73 kg·kg^-1, and the diameter of conveying pipeline was 10 mm. The pipeline thickness of 8-electrode ECT system was 5 mm. An improved AC-based capacitance measuring circuit was developed. Single channel capacitance measuring circuit was adopted to simplify the ECT hardware. Landweber algorithm was used to reconstruct image. The flow characteristics of dense-phase pneumatic conveying was investigated with the method of ECT experiment. Finally, the serial ECT image was compared with the result of Fluent simulation to validate the reliability.
出处 《化工学报》 EI CAS CSCD 北大核心 2009年第4期892-897,共6页 CIESC Journal
基金 国家自然科学基金重点项目(50836003) 国家重点基础研究发展计划项目(2004CB217702)~~
关键词 电容层析成像 厚管壁 气力输送 electrical capacitance tomography thick-pipeline pneumatic conveying
  • 相关文献

参考文献17

  • 1徐越,吴一宁,危师让.二段式干煤粉气流床气化技术的模拟研究与分析[J].中国电机工程学报,2003,23(10):186-190. 被引量:83
  • 2Singer T. Dense-phase pneumatic conveying: applications system design and troubleshooting. Powder and Bulk Engineering, 2003, 17 (3):27-33
  • 3Huang Zhiyao(黄志尧).The application of electrical capacitance tomography in multi phase measurement [D].Hangzhou: Zhejiang University, 1995
  • 4Ostrowski K, Luke S P, Bennett M A, Williams R A. Real time visualisation and analysis of dense phase powder conveying. Powder Technology, 1999, 102 (1) : 1-13
  • 5Artur J Jaworski, Tomasz Dyakowski. Investigations of flow instabilities within the dense pneumatic conveying system. Powder Technology, 2002, 125 (2/3) : 279-291
  • 6杨道业,周宾,许传龙,汤光华,王式民.管道厚度对电容层析成像的影响[J].仪器仪表学报,2008,29(7):1392-1397. 被引量:9
  • 7Jaworski A J, Bolton G T. The design of an electrical capacitance tomography sensor for use with media of high dielectric permittivity. Measurement Science and Technology, 2000, 11 (6) : 743-757
  • 8杨道业,周宾,许传龙,王式民.厚管壁电容层析成像传感器特性研究[J].仪表技术与传感器,2008(5):82-86. 被引量:7
  • 9Yang W Q, York T A. New AC-based capacitance tomography system, IEE Proceedings : Science, Measurement and Technology, 1999, 146 (1):47-53
  • 10Yang Daoye, Xu Chuanlong, Zhou Bin, et al. AC-based capacitance tomography system with small-diameter and high pressure pipe//Cai Xiaoshu. Proe. 5th Intern. Symp.on Measurement Technique for Multi phase Flows. New York: AIP, 2007: 875-885

二级参考文献52

共引文献123

同被引文献199

引证文献12

二级引证文献128

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部