摘要 目的比较经典有机法、改良有机法、常规Chelex-100法、IQ法、Qiagen法及SP法6种方法在提取DNA纯度和得率上的差异。方法收集10名健康志愿者的静脉全血各5mL,分别采用6种方法提取基因组DNA,通过紫外分光光度仪和荧光定量分析技术检测产物的纯度和浓度,计算得率,并使用统计软件对结果进行分析。结果常规Chelex-100法所得DNA的纯度明显低于其他方法,而另外5种方法所得DNA纯度的差异不具有统计学意义。改良有机法得率最低,IQ法得率最高。统计结果表明试剂盒方法抽提全血DNA的得率明显高于经典有机法、常规Chelex-100法和改良有机法,其差异具有统计学意义。结论与有机法和常规Chelex-100法相比,高质量试剂盒类方法更有利于法医学检材的DNA抽提。 Objective Comparing the differences in purity and yield among six methods of extracting human genomic DNA from whole blood, which included Classic Phenol-chloroform extraction, modified combined technique composed of improved Phenol-chloroform extraction and Chelex-100 extraction, Chelex-100 extraction, IQ, Qiagen and SP. Methods Ten samples of intravenous whole blood(5 mL/sample) were collected and human genomic DNA was extracted with these six methods. The purity and concentration of the DNA products were detected by ultraviolet spectrophotometry and fluorescent quantitation technique, the yield was calculated and tested with statistical software. Results The Chelex-100 extraction was inferior in DNA purity to other methods while the other five methods showed no statistical difference. Modified combined technique was the poorest and IQ was the best in yield among the six methods of extraction. Statistical result showed that the extraction with high quality kits was better than that with classic Phenol-chloroform extraction, Chelex-100 extraction and modified combined technique composed of improved Phenol-chloro- form. There was statistical difference between them. Conclusion Comparing to Phenol-chloroform extraction and Chelex-100 extraction, high quality kits are more useful in DNA extraction from forensic materials.
出处 《法医学杂志》 CAS CSCD 2009年第2期109-111,114,共4页 Journal of Forensic Medicine
基金 中央级科研院所社会公益研究专项(GY0805)
关键词 法医遗传学 提取法 试剂盒 诊断 DNA定量 forensic genetics extraction reagent kits, diagnostic DNA quantitative
  • 相关文献

参考文献13

二级参考文献21

  • 1杨电,胡慧英,肖建勇,刘超,李越,刘长晖,陈向红.用拭子提取脱落细胞进行DNA检验[J].中国法医学杂志,2004,19(S1):24-25. 被引量:3
  • 2顾丽华,平原,程莉,周怀谷.模板DNA用量对荧光STR复合扩增检测的影响[J].中国法医学杂志,2002,17(2):77-80. 被引量:14
  • 3[1]Walsh Ps, Metzgar DA, Higuchi R. Chelex-100 as a medium for simple exrtaction of DNA for PCR-based typing from forensic material [J].Biotechniques, 1991,10(4):506.
  • 4[3]裴黎,王俭,邓华,等.用毛细管电泳技术对北京汉族人群9个STR基因座遗传多态性的研究[C].首届中国警察科学技术研讨会论文集,2001,86-89.
  • 5[1]Promega公司.DNA IQTM系统小样品案例操作手册[Z].
  • 6[2]The Applied Biosystems Corporation.QuantifilerTM Kits User's Manual[Z].
  • 7[3]The Applied Biosystems Corporation.AmpFlSTR IdentifilerTM PCR Amplification Kit User's Manual[Z].4-44-52.
  • 8Bielawski K, Zaczek A, Lisowska U, et al. The suitability of DNA extracted from formalin fixed, paraffin embedded tissues for double differential polymerase chain reaction analysis[J]. Int J Mol Med, 2001, 8(5):573.
  • 9Chan P K, Chan D P, To K F, et al. Evaluation of extraction methods from paraffin wax embedded tissues for PCR amplification of human and viral DNA[J]. J Clin Pathol, 2001, 54(5):401.
  • 10Roy R, Steffens D L, Gartside B, et al. Producing STR locus patterns from bloodstains and other forensic samples using an infrared fluorescent automated DNA sequencer[J]. J Forensic Sci, 1996, 41(3):418.