摘要 对于同步建设烟气脱硫装置的发电工程,应统筹规划、统一设计发电的排烟和烟气脱硫设施,设置单一的风机排放烟气,达到运行可靠、调节快捷和经济安全的目的。以典型的600MW发电工程的设计数据为依据,对脱硫增压风机与锅炉引风机分别设置和合并设置2种方案进行技术比较和经济指标分析,论述锅炉引风机与脱硫增压风机合一的优势。 In order to attain reliable operation, rapid control, economical efficiency and safety, this paper proposes overall planning and unified designing for the flue gas discharge system and the flue gas desulfurization (FGD) system for the power plant project in which the FGD facilities are provided and constructed at the same time with the generation units, and it also puts forward the idea of a single fan to discharge flue gas. Based on the design data of a typical 600 MW plant project, the paper makes a technical and economic comparison of both the separated design and the unified design of the desulphurization booster fan and the boiler induced draft fan, elaborating on the advantages of the integrated design.
出处 《电力技术经济》 2009年第2期31-34,共4页 Electric Power Technologic Economics
关键词 电力技术经济 脱硫系统 增压风机 引风机 power techno-economics desulphurization system booster fan induced draft fan
  • 相关文献

参考文献2

二级参考文献5

  • 1曾庭华 杨华 王斌.湿法烟气脱硫系统的安全性及优化[M].北京:中国电力出版社,2003..
  • 2GB 13223-2003火电厂大气污染物排放标准[S].北京:中国标准出版社.2003.
  • 3蒋丛进,王文杰,张忠梅,等.三河电厂二期烟气脱硫工程工艺及吸收塔核心设计[R].2005.
  • 4许涛,孙芳.脱硫风机的研究与应用[J].山东电力技术,2000,27(3):8-11. 被引量:2
  • 5顾恒庆,万方.电站大型风机的选择[J].热机技术,2001(1):21-23. 被引量:4