摘要
结合震后重建的某镇中心学校的电气设计,探讨了震区中小学校电气设计中配电系统、照明、防雷与接地等几方面需要注意的问题,介绍在设计中采用的一些防震措施(充分考虑震区特点,对安全性尤为重视)。
Combined with the electrical design for the post-earthquake reconstruction of a town central school, Problems in several aspects, such as distribution system, lighting, lightning protection and grounding in the electrical design of primary and middle schools in earthquake region are discussed. Some measures against earthquakes (which is considered fully the characteristics of earthquake region, and particularly emphasis on the security) adopted in the design are also introduced.
出处
《建筑电气》
2009年第4期54-56,共3页
Building Electricity
关键词
震区
学校
电气设计
防震
Earthquake region Schools Electrical design Quakeproof