摘要
实验研究表明,游泳池循环水运行管理中消毒剂用量主要与池水浊度、水温、pH及时间有关,且随各指标数值的增高而增加.夏季可适当降低加热温度,并相应增加混凝剂的投放次数,既可降低消毒剂的用量,同时又可保障池水的安全性;在pH值在中性以上时应适当将其调整为偏酸性,不仅可减少消毒剂的用量,还可提高池水消毒效果.
The results of the experiment suggested that the amount of disinfectant used during the management of circulating water system of swimming pool mainly connects with water turbidity, water temperature, pH value and time. It increases with the rise of those index values. The heating temperature could be reduced suitably while adding the coagulant to the pool more frequently. This can help decrease the usage of disinfectant and ensure the security of the pool water. Once the pH value is above neuter, it should be adjusted to weak acidity in order to reduce the usage of disinfectant and increase the efficiency of disinfection.
出处
《内蒙古科技大学学报》
CAS
2008年第4期381-382,388,共3页
Journal of Inner Mongolia University of Science and Technology
关键词
游泳池
消毒
浊度
水温
PH
swimming pool
disinfection
turbidity
water temperature
pH value