期刊文献+

ICP-MS测定高纯金中的杂质元素 被引量:24

Determination of impurity element in high-purty gold by ICP-MS
下载PDF
导出
摘要 建立了一种高纯金中36种杂质元素的电感耦合等离子体质谱测定方法,通过加入内标元素Sc、Cs和Re,以及采用加入校正的方式,有效地补偿了测定中的基体效应。仪器检测限为0.000 4-0.123 1μg/mL,方法检测限为0.2-2.0μg/g,加入标准物质的回收率为91%~117%,分析精密度为0.35%-4.80%。 The method of inductively coupled plasma-mass spectrometry for the determination of 36 inpurity elements in high-purty gold is studied.With Sc,Cs and Re as internal standard elements and the correction method of standard additions,the interference of the matrix effects could be corrected effectively.The determination limit of spectrometry is 0.000 4~0.123 1μg/mL.The determination limit of the method is 0.2~2.0μg/g.The recoveries of standard elements are 91%~117%,and the relative standard deviation(RSD) is between 0.35%~4.80%.
机构地区 长春黄金研究院
出处 《黄金》 CAS 北大核心 2009年第4期43-47,共5页 Gold
关键词 电感耦合等离子体质谱 内标法 加入校正法 高纯金 ICP-MS internal standard method standard addition correction method high-purty gold
  • 相关文献

参考文献2

二级参考文献2

共引文献26

同被引文献674

引证文献24

二级引证文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部