被动式太阳能建筑夏季降温实验研究 被引量:3

Experimental Study on Cooling Method of Passive Solar House
下载PDF
导出
摘要 大量的应用及研究表明,夏季过热现象是制约被动式太阳能采暖技术应用的关键问题之一。本文通过对建于大连理工大学校园内的太阳能空气集热模块实验设施的夏季降温实验,在分析大连地区的夏季自然降温潜力的基础上,重点讨论了夜间通风与室内热质结合、集热模块的遮阳与通风方式等措施对缓解夏季过热程度的作用。实验结果表明,集热模块的通风与遮阳能有效降低南墙壁面温度,夜间通风与热质结合时至少能降低室内温度1~2℃。 The applications and studies have shown that overheating in summer is one of the key issues which restrict the application of passive solar heating technology. The paper, which introduces the summer cooling experiment of the passive solar building coupled with solar air collector module, based on the analysis of natural cooling potential in summer of Dalian, emphasizes on the effect of night ventilation combined with thermal mass, ventilation, etc. The results show that sunshade and ventilation of the collector module have good effect on the south wall temperature, thermal mass of the roof can delay and decrease outdoor temperature wave, night ventilation combined with thermal mass can reduce the indoor temperature of 1 - 2℃.
作者 王小林 陈滨
出处 《建筑热能通风空调》 2009年第2期1-4,共4页 Building Energy & Environment
关键词 被动式太阳房 夏季过热 夜间通风 热质 passive solar house, overheat in summer, night ventilation, thermal mass
  • 相关文献

参考文献9

  • 1Akbari H, Bretz S, Kum DH, et al. Peak power and cooling energy savings of high albedo roofs [J]. Energy and Buildings, 1997, 25(2): 117-126
  • 2Raeissi S, Taheri M. Energy saving by proper tree plantation [J]. Building and Environment, 1999, 34(5): 565-570
  • 3Bojic M, Yik F, Sat P. Influence of thermal insulation position in building envelope on the space cooling of high-rise residential building in Hong Kong [J]. Energy and Buildings, 2001, 33 (6): 569-581
  • 4陈滨,陈星,丁颖慧,陈会娟.冬季特朗贝墙内置卷帘对墙体热性能的影响[J].太阳能学报,2006,27(6):564-570. 被引量:16
  • 5Shaviv E, Yezioro A, Capeluto IG. Thermal mass and night ventilation as passive cooling design strategy [J]. Renewable Energy, 2001, 24(3): 445-452
  • 6Finn D, Connolly D, Kenny P. Sensitivity analysis of a maritime located night ventilated library building [J]. Solar Energy, 2007, 81(12): 697-710
  • 7Akbari H, Samano D, Mertol A, et al. The effect of variations in convective coefficients on thermal energy storage in buildings: Part I-interior partition walls [J]. Energy and Buildings, 1986, 9 (3): 195-211
  • 8Sas o, Medved, Ciril Arkar. Correlation between the local climate and the free-cooling potential of latent heat storage [J]. Energy and Buildings, 2008, 40(4): 429--437
  • 9N Artmann, H Manz, P Heiselberg. Parameter study on performance of building cooling by night-time ventilation [J]. Renewable Energy, 2008, 33(12): 2589-2598

二级参考文献6

共引文献15

同被引文献30

引证文献3

二级引证文献4