期刊文献+

130t/h燃生物质锅炉过热器管子腐蚀原因分析 被引量:11

Cause Analysis on Corrosion of a 130 t/h Biomass-fired Boiler's Superheater Tubes
下载PDF
导出
摘要 某燃生物质锅炉在运行中过热器出现泄漏,经检查发现过热器管子腐蚀,通过对管材进行理化分析,对管外垢样进行能谱分析、原子吸收分析、熔融试验分析及X射线衍射分析,对生物质燃料灰成分分析和灰熔点分析,对过热器结构进行分析,得出过热器管腐蚀主要是由于管子多次持续超温,以及在高温下碱金属氯化物和硫化物对管壁金属的腐蚀等因素引起的,从而提出了相应的解决措施。 Leakage failure was encountered by the superheater of a biomass-fired boiler during operation where tube corrosion was found. Based on a series of analysis respectively on the tube material, surface scale, fuel ash as well as structure of the superheater, the corrosion was found to be caused by repeated overheating and existence of alkali chloride and sulfide. In order to solve above problems, corresponding countermeasures are proposed.
出处 《发电设备》 2009年第3期214-218,共5页 Power Equipment
关键词 锅炉 生物质燃料 过热器 腐蚀 过热 boiler biomass fuel superheater corrosion overheating
  • 相关文献

参考文献1

  • 1龚淘洁.热力设备的腐蚀与防护[M].北京:中国电力出版社,1998.

共引文献1

同被引文献105

引证文献11

二级引证文献71

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部