期刊文献+

轻钢龙骨墙体经济性研究 被引量:5

ECONOMIC RESEARCH ON LIGHT GAUGE STEEL-FRAMED RESIDENTIAL CONSTRUCTION COMPOSITE WALLS
下载PDF
导出
摘要 采用黑龙江省相关定额作为计价依据,进行了轻钢龙骨复合墙体价格组成分析。为使轻钢龙骨复合墙体满足哈尔滨地区建筑外墙节能标准,依据保温性能相近原则,进行了轻钢龙骨墙体与8种常用墙体的造价、自重和占用空间对比分析。分析表明,轻钢龙骨复合墙体的价格在100~180元/m2之间,其中材料价格组成中岩棉所占比重最大,占总价格的40%~50%;龙骨腹板开孔后墙体材料价格升高0.4%~0.5%,加20mm厚苯板外保温后墙体材料价格升高13%~20%。对比分析表明,轻钢龙骨墙体具有保温性能优越、价格适中、墙体厚度小等特点,综合效益突出,具有在哈尔滨地区推广使用的前景。 Using the relevant estimate in Heilongjiang Province as the basic price,the price composition analysis of light gauge steel-framed composite wall has been carried on.To make the light gauge steel-framed composite wall meet construction outer wall energy conservation standard in Harbin area,according to the close principle of the heat preservation performance,a contrast analysis was done among the cost,self weight and occupied space of the light gauge steel-framed composite wall and the other eight kinds of commonly used walls.The rsults showed that of the price of light gauge steel-framed composite wall between in 100~180 yuan per square meter,of which material price of rock cotton was 40%~50% of total price.After adding slots to the web plate of stud in light gauge steel-framed composited wall,the material price of the wall was elevated by about 0.4%~0.5%,adding the 20 mm benzene board in the outside of the wall,the material price of the wall was raised by about 13%~20%.The contrast analysis indicated that the light gauge steel-framed composite wall has many characteristics such as the superior heat preservation performance,middle price and less thickness of the wall and so on,the comprehensive benefit is prominent,which is worth promoting in Harbin area.
出处 《钢结构》 2009年第4期49-53,共5页 Steel Construction
基金 哈尔滨市墙体材料改革与建筑节能科学研究资助项目。
关键词 轻钢龙骨住宅体系 外墙外保温 腹板开缝龙骨 平均传热系数 light gauge steel-framed residential construction external thermal insulation of outer wall slotted steel studs in the web plate mean heat transmission coefficient
  • 相关文献

参考文献7

二级参考文献20

共引文献365

同被引文献23

  • 1李远瑛,江风波,朱平华,蒋沧如.轻钢龙骨复合墙体抗侧性能试验研究[J].建筑科学,2006,22(4):32-35. 被引量:7
  • 2蔡江勇,刘志会,蒋沧如,王小平,李书进.轻钢骨架-覆面结构板材组合墙体抗侧力性能的试验[J].工业建筑,2007,37(6):80-82. 被引量:4
  • 3黑龙江省建设委员会.黑龙江省建设工程预算定额(土建)[M].哈尔滨:黑龙江科学技术出版社,2000.
  • 4Kosny J, Christian J E. Thermal Evaluation of Several Configurations of Insulation and Structural Materials for Some Metal Stud Walls [ J ]. Energy and Buildings, 1995,22 : 157 - 163.
  • 5Kosny J, Christian J E. Reducing the Uncertainties Associated with Using the ASHRAE Zone Method for R-Value Calculations of Metal Frame Wails [ R ]. ASHRAE Transactions, 1995 : 779 -.
  • 6Barbour C E, Goodrow J. The Thermal Performance of Steel- Framed Walls [ R ]. ASHRAE Transactions, 1995:766 - 778.
  • 7Salonvaara M, Nieminen J. Hygrothermal Performance of a New Light Gauge Steel-Framed Envelope System [R]. ASHRAE Transactions, 1998 : 1256 - 1262.
  • 8章熙民,任泽霈,梅飞鸣.传热学[M].4版.北京:中国建筑工业出版社,2003.
  • 9GB50018-2002.冷弯薄壁型钢结构技术规范[S].[S].,..
  • 10JGJ26-95.民用建筑节能设计标准(采暖居住建筑部分)[s].[S].,..