摘要 目的 探讨常规腹部多期增强扫描后,行动脉期、门静脉期血管编辑减影成像的可行性。资料与方法选择行腹部多期增强扫描患者68例。男40例,女28例,年龄14~83岁,平均47.5岁。扫描设备为Siemens Somatom Sensation16层螺旋CT,处理软件为设备所带3D卡中的常规软件objecteditor。同一定位像下行平扫及多期增强扫描,对平扫薄层图像进行骨骼对象编辑后保存至3D Application Data,利用此数据进行编辑减影去骨处理,完成动脉期、门静脉期血管成像。结果68例中,除2例因身体移动不能编辑减影外,余66例均编辑减影成功,均较好完成血管成像,其中,图像质量评为4分者39例,占59%;3分21例,占32%;2分6例,占9%;无一例图像被评为1分。整个过程约1~7min,平均2min。结论多层螺旋CT腹部编辑减影血管成像技术可以方便、快捷地完成去骨,清晰显示腹部血管。 Objective To evaluate the feasibility and clinical application of multislice spiral CT subtraction edited angiography for artery and portal vein in abdomen multi-phase enhancement scanning. Materials and Methods 68 cases with abdomen multi-phase enhancement scanning were collected. The plain and multi-phase enhancement scanning were finished in the same scour range, skeleton target were edited in thin slice picture and preserved to 3D Application Data,subtraction edited bone removing were carried out, and the angiography for artery and portal vein in abdomen were finished. Results 66 eases were succeeded except 2 cases whose bodies moved, among them, there were 39 cases (59% ,39/66) whose picture quality were assessed as score of 4, and score of 3 were 21 cases (32% ,21/66) ; score of 2 were 6 cases (9% , 6/66) ; there was no picture to appraise as score of 1. The whole course needed about 1 -7minutes,average 2 minutes. Conclusion The technology, of subtraction edited angiography for artery and portal vein in abdomen multi-phase scanning is convenient and rapid to complete bone removing,and reveal the abdomen blood vessel clearly.
出处 《临床放射学杂志》 CSCD 北大核心 2009年第4期556-559,共4页 Journal of Clinical Radiology
基金 珠海市科技计划项目(编号:PC20071066)
关键词 血管成像 腹部 体层摄影术 X线计算机 Angiography Abdomen Tomograph, X-ray computed
  • 相关文献

参考文献8

  • 1Fishman EK. CT angiography:clinical applications in the abdomen. RadioGraphic,2001,21:3.
  • 2陈青华,柳澄.腹部螺旋CT血管成像技术[J].中国医学影像技术,2004,20(4):641-644. 被引量:29
  • 3柳澄.多层螺旋CT应用中3个混乱概念的澄清[J].医学影像学杂志,2002,12(6):467-468. 被引量:10
  • 4Kirchner J, Kickth R, Laufer U,et al. Optimized enhancement in helical CT:experiences with a real time bolus tracking system in 628 patients. Clin Radio1,2000,55:368.
  • 5Rieker O, Duber C, Pitton M, et al. CT angiography versus intraarterial digital subtraction angiography for assessment of aortliliac occlusive disease. AJR, 1997,169 : 1133.
  • 6苑静波,刘冲,贾丽英,赵青,叩新军,徐丽梅.多层螺旋CT腹部血管成像应用研究[J].实用放射学杂志,2005,21(8):843-845. 被引量:20
  • 7周康荣.螺旋CT[M].上海:上海医科大学出版社,1999.6—10.
  • 8Hong H, Lee H, Shn YG, et al. Automaticvessel extraction by patient motion correction and bone removal in brain CT angiography. Int Congress Series ,2005,1281:369.

二级参考文献26

  • 1Fishman EK.CT angiography:Clinical applications in the abdomen[J].Radiographic,2001,21(5):S3-S16.
  • 2Chow LC,Rubin GD.CT angiography of the arterial system[J].Radiol Clin North Am,2002,40(4):729-749.
  • 3Rubin GD,Dake MD,Semba CP.Current status of three-dimensional spiral CT scanning for imaging the vasculature[J].Radiographics,2002,22 (5):S3-S19.
  • 4Johnson PT,Heath DG,Kuszyk BS,et al.CT angiography with volume rending:advantages and applications in splanchnic vascular imaging[J].Radiology,1996,200(3):564-568.
  • 5Kuszyk BS,Heath DG,Ney DR,et al.CT angiography with volume rending:imaging findings[J].AJR,1995,165(2):445-448.
  • 6Kelingenbeck Regn K,Schaller S,Flohr T,et al.Subsecond multi-slice computed tomography:basics and applications[J].Eur J Radiol,1999,31(2):110-124.
  • 7Brink JA.Technical aspects of helical (spiral) CT[J].Radiol Clin North Am,1995,33(5):825-841.
  • 8Luboldt W,Weber R,Seemann M,et al.Influence of helical CT parameters on spatial resolution in CT angiography performed with a subsecond scanner[J].Invest Radiol,1999,34(6):421-426.
  • 9Heuscher DJ,Vembar M.Reduced partial volume artifacts using spiral computed tomography and an integrating interpolator[J].Med Phys,1999,26(2):276-286.
  • 10Hu H,Fox SH.The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging[J].Med Phys,1996,23(12):1943-1954.

共引文献65

同被引文献23

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部