冷激气压缩机是壳牌粉煤气化装置的一个核心设备,它运行的好坏直接影响到气化炉的安全稳定运行;通过分析试开车中出现重大故障的原因和解决措施,为其他同类型的装置运行提供借鉴和参考。
Analyzed reasons for severe failure of quenching gas compressor during commissioning, and proposed method to solve the problem. The method, including phenomena judgment, reason analysis, demonstration and disturbance elimination, was used, and the failure was thoroughly eliminated in one time. Seen from the operation, it' s shown that the method is correct and effective, providing strong basis for safe and stable operation of coal gasification plant.
出处
《大氮肥》
CAS
2009年第2期85-87,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
冷激气压缩机
煤气化
合成氨
振动