期刊文献+

氢化物发生-原子荧光光谱法测定铅锌矿中微量铋 被引量:1

HG-AFS determination of trace bismuth in lead-zinc ore
下载PDF
导出
摘要 通过对仪器测定条件和氢化反应介质、酸度及硼氢化钾的浓度等试验条件的优化选择,建立了HG-AFS测定铅锌矿中微量铋的分析方法,并考察了方法的精密度、准确度和检出限.实验结果表明:仪器测量精密度(RSD)为1.93%,试样测量精密度(RSD)为3.04%,加标回收率为95.3%~102.1%,检出限为0.08μg/L.若以0.5 g试样最后定容至50 ml计算,试样的最低检出限为0.008μg/g. To optimize the choice of measure device, Hydrogenation media, acidity and concentration of potassium borohydride, and other experimental conditions. A determination and analytical methods for trace bismuth in lead-zinc by using the HG-AFS have been establish in the paper. The methods also have been inspected for its precise, accuracy and detection limit. The test results are as: precision measuring instruments (RST) was 1.93 percent, the sample measurement precision (RSD) was 3.04%, recoveries 95.3%~102.1% for the detection limit of 0.08μg/L. In terms of 0.5g sample to 50 ml final volume terms, the minimum sample detection limit of 0.008μg/L.
出处 《韶关学院学报》 2009年第3期74-77,共4页 Journal of Shaoguan University
关键词 氢化物发生 原子荧光 微量铋 hydride generation atomic fluorescence micro-Bi
  • 相关文献

同被引文献395

引证文献1

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部