期刊文献+

Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2

Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings
下载PDF
导出
摘要 The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页 华中科技大学学报(医学英德文版)
基金 supported by a grant from the Youth Science Foundation of China (No.30600213)
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
  • 相关文献

参考文献9

  • 1Cheng TO,Xie MX,Wang XF,et al.Real-time 3-Dimensional echocardiography assessing Atrial and ventricular septal defects:An echocardiographic-surgical correlative study[].American Heart Journal.2004
  • 2Franke A,Rulands D,Kuhl HP,et al.Changes of atrial septal defect area during the cardiac cycle:evaluation of dynamic transoesophegeal three dimensional echocardio-graphy(Abstract)[].European Heart Journal.1996
  • 3Marx G R,Fulton D R,Pandian N G,et al.Delineation of site, relative size, and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography[].Journal of the American College of Cardiology.1995
  • 4Thanopoulos B D,Laskari C V,Tsaousis G S,et al.Closure of atrial septal defects with Amplatzer occlusion device: priliminary results[].Journal of the American College of Cardiology.1998
  • 5Wang XF,Deng YB,Nanda NC,et al.Live three-dimensional echocardiography: imaging principles and clinical application[].J Echocardiography.2003
  • 6Houck RC,Cooke JE,Gill EA.Live3D echocardiography:a re-placement for traditional2D-echocardiography[].American Journal of Roentgenology.2006
  • 7Balestrini L,Fleishman C,Lanzoni L,et al.Real -time 3-dimensional echocardiography evaluation of congenital heart disease[].Journal of the American Society of Echocardiography.2002
  • 8Acar,P.,Roux,D.,Dulac,Y.Transthoracic three-dimensional echocardiography prior to closure of atrial septal defects in children[].Cardiology in the Young.2003
  • 9Kannan BR,Francis E,Sivakumar K,et al.Transcatheter closure of verylarge(25mm)atrial septal defects using the Amplatzer septal occluder[].Catheterization and Cardiovascular Interventions.2003

同被引文献3

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部