摘要
论文对成渝高速公路中的中梁山公路隧道的运营现状进行了介绍,针对隧道内和隧道出口处CO浓度过大,VI较小等环境问题进行了详细的陈述与分析,继而对该环境问题所导致的隧道监控室内监控人员工作环境较差,对周围环境的影响较大等状况进行了细致地阐述,并综合给出了几种可行的改造方案,从造价及对周围环境的影响等方面进行了详细的对比分析,最后给出了切实可行的建议方案。
the paper describes the management about the zhonglianshan road tunnel belonging to the chenyu expressway. For the GO is much higher and the VI is much lower than the criterion inside of the tunnel and around the exit of the tunnel, the environment nearby the tunnel is polluted seriously and the monitoring room's polluted air makes the people that work here feel uncomfortable. This bad status also makes the traffic accident improved. These instances are detailed analyzed and several viable methods to deal with the pollution are given. At last, the paper contrasts these methods' characteristic.
出处
《地下空间与工程学报》
CSCD
北大核心
2009年第2期325-328,335,共5页
Chinese Journal of Underground Space and Engineering
基金
重庆自然科学基金项目(CSTC,2007BB6434)