摘要 以Biosampler采样器为参照,采用平行重复的实验方法,以电压和流量作为匹配因素结合ELISA、LAL和GLU-CANTELL技术,检测空气中过敏原Der p和Der f及内毒素和多聚糖。结果表明,静电场采样装置对4种生物气溶胶的采集效率要比Biosampler采样器高2倍~8倍,静电场采样法优于撞击式采样法。 Der p,Der f,endotoxin and glucan were collected in parallel and repeatedly by electrostatic sampling devices and biosampler and their concentrations were measured by ELISA,LAL and GLUCANTELL methods.The results showed that the sampling efficiency of electrostatic sampling devices were about 2~8 times higher than biosampler's when collecting the airborne allergens and toxins.The effect of electrostatic sampling was observed better than the impactor.The electrostatic field sampling devices needed to be further improved.
出处 《环境监测管理与技术》 2009年第2期57-59,共3页 The Administration and Technique of Environmental Monitoring
基金 2007年江苏省科技计划基金资助项目(BS2007069)
关键词 静电场采样器 室内空气 过敏原 Derp Derf 内毒素 多聚糖 Electrostatic field sampler Indoor air Allergen Der p Der f Endotoxin Glucan
  • 相关文献

参考文献10

  • 1BURR M L, MULLINS J,MERRETT T G, et al. Indoor molds and asthma [ J ]. Royal Society of Health, 1988,108 ( 3 ) : 99 - 101.
  • 2MICHEL O, KIPS J, DUCHATEAU J, et al. Severity of asthma is related to endotoxin in house dust[ J]. American Journal of Respiratory and Critical Care Medicine, 1996,154 (6) : 1641 - 1646.
  • 3LIN X, REPONEN T, WILLEKEI K, et al. Survival of airborne microorganisms during swirling aerosol collection [ J ]. Aerosol Science and Technology,2000,32 : 184 - 196.
  • 4MAOSHENG Y, MAINELIS G. Utilization of natural electrical charges on airborne microorganisms for their collection by electrostatic means [ J ]. Aerosol Science, 2006, 37 (4) : 513 - 527.
  • 5VERHOEFF A P, BURGE H A. Health risk assessment of fungi in home environments[ J]. Annals of Allergy, Asthma & Immunology, 1997,78 ( 6 ) : 544 - 554.
  • 6PASANEN A L. Review: Fungal Exposure Assessment in Indoor Environments[ J]. Indoor Air, 2001, 11:87 -98.
  • 7GRAHAM J A H, PAVLICKER P K, SERCOMBE J K, et al. The nasal air sampler: a de vice for sampling inhaled aeroallergens[ J]. Annals of Allergy, Asthma & Immunology, 2000,84 (6) :599 -604.
  • 8RYLANDER R. Airborne ( 1,3 ) -β-D-Glucan and airway disease in a day-care center before and after renovation [ J ]. Archives of Environmental Health, 1997, 52:281 - 285.
  • 9HAMMOND S K, SUGIURA M, NOTH E M, et al. Airborne endotoxin inside and outside homes in the Fresno (CA) Asthmatic Children 's Environment Study (FACES) [ Abstract ] [J]. Respir Crit Care Med, 2003, 167:7.
  • 10CDC. Heahh concerns associated with mold in water-damaged homes after Hurricanes Katrina and Rita-New Orleans area, Louisiana [ R ]. MMWR Morbid Mortal Wkly Rep, 2006,55 (2) :41 -44.