期刊文献+

流动注射小柱预富集-石墨炉原子吸收联用分析茶汤和水样中不同形态的铝 被引量:2

Flow Injection Column Preconcentration Coupled with ETAAS for the Speciation of Al in Tea Infusion and Water Samples
下载PDF
导出
摘要 将装有8-羟基喹啉修饰的玻璃小珠或XAD-2聚合物小球的微型富集分离柱接入流动注射-石墨炉原子吸收联用系统,分析茶汤和水样中不同形态的铝.选择不同的富集分离条件,样品中的铝可被分为与8-羟基喹啉快速络合的无机态铝、有机疏水态铝和总铝等几个种类,并比较和讨论实验结果. A method has been developed for the speciation analysis of Al in teainfusion and water samples using an automated online preconcentration system with flow injection coupled directly to an electrothermal atomic absorption spectrometer. Two preconcentration materials, 8quinolinol immobilized on controlledpore glass and Amberlite XAD2 copolymer, were investigated. Al in the sample could be distinguished as fast exchangeable Al, hydrophobic Al, and total Al, based on the preconcentration conditions.
出处 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 1998年第1期80-87,共8页 Journal of Xiamen University:Natural Science
基金 福建省自然科学基金
关键词 形态分析 流动注射 原子吸收光谱 Al, Speciation, Flow injection, Atomic absorption Spectrometry
  • 相关文献

参考文献2

  • 1袁东星,Anal Chim Acta,1995年,316卷,313页
  • 2Chakrabarti C L,Anal Chim Acta,1993年,276卷,47页