期刊文献+

循环水地下钢制管道的腐蚀

Corrosion of Underground Cooling Water Steel Pipeline
下载PDF
导出
摘要 介绍了循环水地下回水管道引起腐蚀泄漏的失效分析情况,认为管道主要腐蚀形式为局部点蚀.穿孔的原因除防护层的缺陷外,主要是由于静电接地铜极与钢管的距离太近、发生电偶腐蚀所致;并介绍了所采取的防护措施. The analysis of the corrosion failure of the underground cooling water pipeline was described. It was concluded that the main form of corrosion of the pipeline was the pitting corrosion resulted from galvanic corrosion because of too a short distance between grounding copper and steel pipeline an addition besides the defects of protection coating. The protection measures taken were introduced.
出处 《石油化工腐蚀与防护》 CAS 1998年第1期35-36,共2页 Corrosion & Protection In Petrochemical Industry
关键词 地下管道 涤纶厂 循环水 腐蚀 防护 underground pipeline, grounding copper, galvanic corrosion