摘要
煤矿井下电机车牵引网络的杂散电流是引发瓦斯爆炸和雷管先期引爆的原因之一。通过对杂散电流形成机理的分析讨论,提出了防治杂散电流的必要措施。
The stray current resulted from the traction networks of electrical locomotives is one of the causes of gas explosion and premature explosion from detonator. By discussing the generation mechanism of stray current,the necessary measures for preventing and controlling stray current are suggested in this paper.
出处
《太原理工大学学报》
CAS
1998年第3期237-239,243,共4页
Journal of Taiyuan University of Technology
基金
煤炭部留学生科技基金
关键词
电机车牵引
杂散电流
数学模型
煤矿
stray current
electric locomotive traction
mathematical model